Back to Search Start Over

Q waves are the strongest electrocardiographic variable associated with primary prophylactic implantable cardioverter-defibrillator benefit: a prospective multicentre study.

Authors :
Pelli A
Junttila MJ
Kenttä TV
Schlögl S
Zabel M
Malik M
Reichlin T
Willems R
Vos MA
Harden M
Friede T
Sticherling C
Huikuri HV
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2022 May 03; Vol. 24 (5), pp. 774-783.
Publication Year :
2022

Abstract

Aim: The association of standard 12-lead electrocardiogram (ECG) markers with benefits of the primary prophylactic implantable cardioverter-defibrillator (ICD) has not been determined in the contemporary era. We analysed traditional and novel ECG variables in a large prospective, controlled primary prophylactic ICD population to assess the predictive value of ECG in terms of ICD benefit.<br />Methods and Results: Electrocardiograms from 1477 ICD patients and 700 control patients (EU-CERT-ICD; non-randomized, controlled, prospective multicentre study; ClinicalTrials.gov Identifier: NCT02064192), who met ICD implantation criteria but did not receive the device, were analysed. The primary outcome was all-cause mortality. In ICD patients, the co-primary outcome of first appropriate shock was used. Mean follow-up time was 2.4 ± 1.1 years to death and 2.3 ± 1.2 years to the first appropriate shock. Pathological Q waves were associated with decreased mortality in ICD patients [hazard ratio (HR) 0.54, 95% confidence interval (CI) 0.35-0.84; P < 0.01] and patients with pathological Q waves had significantly more benefit from ICD (HR 0.44, 95% CI 0.21-0.93; P = 0.03). QTc interval increase taken as a continuous variable was associated with both mortality and appropriate shock incidence, but commonly used cut-off values, were not statistically significantly associated with either of the outcomes.<br />Conclusion: Pathological Q waves were a strong ECG predictor of ICD benefit in primary prophylactic ICD patients. Excess mortality among Q wave patients seems to be due to arrhythmic death which can be prevented by ICD.<br /> (© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.)

Details

Language :
English
ISSN :
1532-2092
Volume :
24
Issue :
5
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
34849744
Full Text :
https://doi.org/10.1093/europace/euab260