Back to Search
Start Over
[Effectiveness and safety of robotic assisted-bronchoscopy system in locating and removing spring coils placed in the peripheral lung of beagle dogs: a pilot study].
- Source :
-
Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases [Zhonghua Jie He He Hu Xi Za Zhi] 2021 Dec 12; Vol. 44 (12), pp. 1071-1077. - Publication Year :
- 2021
-
Abstract
- Objective: To evaluate the effectiveness and safety of the robotic assisted bronchoscope system for localizing and removing the spring coils that placed in the peripheral lung of beagle dogs. Methods: The study was conducted from June 18th to June 20th, 2021. Metallic lung coils were placed as the simulated lesions to the periphery of the lungs of two adult male beagle dogs using a bronchoscope under general anesthesia. The navigation path was planned by the navigation function that built in the robotic bronchoscope system. After training, the doctors operated the robotic bronchoscope system to locate and remove the coils from the lung. The navigation success rate, sampling success rate, position of the coil, navigation time, sampling time, and operation time were evaluated. The damage to the airway mucosa during the operation and the vital signs of the beagles during and post-operation were accessed. Chest computerized tomography (CT) was performed post-operation to detect if there were complications such as pneumothorax and bleeding. Results: A total of 12 spring coils were successfully inserted into the two beagles. All the navigation paths of the simulated lesions were successfully planned. The navigation success rate was 12/12. The navigation time was (43.9±19.8) seconds. The distance between the tip of the flexible endoscope arm and the target point measured by the navigation system was (6.93±2.15) mm. The locations of the simulated lesions were distributed in the 6th-8th generation of bronchi. The sampling success rate was 12/12. The sampling time was (42.4±11.3) seconds. There was no pneumothorax or mediastinal emphysema after the placement of the coil. The vital signs of the beagle dogs were stable throughout the operation, and no operation-related or postoperative complications occurred. Conclusions: The robotic bronchoscope system can be used to locate and remove the spring coils from the peripheral lung of beagle dogs, and the procedure is simple and safe. It suggests that the robotic bronchoscopy system has great clinical significance in the sampling and diagnosis of peripheral lung lesions.
Details
- Language :
- Chinese
- ISSN :
- 1001-0939
- Volume :
- 44
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases
- Publication Type :
- Academic Journal
- Accession number :
- 34915620
- Full Text :
- https://doi.org/10.3760/cma.j.cn112147-20210802-00541