Back to Search Start Over

Automatic segmentation of head and neck primary tumors on MRI using a multi-view CNN.

Authors :
Schouten JPE
Noteboom S
Martens RM
Mes SW
Leemans CR
de Graaf P
Steenwijk MD
Source :
Cancer imaging : the official publication of the International Cancer Imaging Society [Cancer Imaging] 2022 Jan 15; Vol. 22 (1), pp. 8. Date of Electronic Publication: 2022 Jan 15.
Publication Year :
2022

Abstract

BACKGROUND : Accurate segmentation of head and neck squamous cell cancer (HNSCC) is important for radiotherapy treatment planning. Manual segmentation of these tumors is time-consuming and vulnerable to inconsistencies between experts, especially in the complex head and neck region. The aim of this study is to introduce and evaluate an automatic segmentation pipeline for HNSCC using a multi-view CNN (MV-CNN).<br />Methods: The dataset included 220 patients with primary HNSCC and availability of T1-weighted, STIR and optionally contrast-enhanced T1-weighted MR images together with a manual reference segmentation of the primary tumor by an expert. A T1-weighted standard space of the head and neck region was created to register all MRI sequences to. An MV-CNN was trained with these three MRI sequences and evaluated in terms of volumetric and spatial performance in a cross-validation by measuring intra-class correlation (ICC) and dice similarity score (DSC), respectively.<br />Results: The average manual segmented primary tumor volume was 11.8±6.70 cm <superscript>3</superscript> with a median [IQR] of 13.9 [3.22-15.9] cm <superscript>3</superscript> . The tumor volume measured by MV-CNN was 22.8±21.1 cm <superscript>3</superscript> with a median [IQR] of 16.0 [8.24-31.1] cm <superscript>3</superscript> . Compared to the manual segmentations, the MV-CNN scored an average ICC of 0.64±0.06 and a DSC of 0.49±0.19. Improved segmentation performance was observed with increasing primary tumor volume: the smallest tumor volume group (<3 cm <superscript>3</superscript> ) scored a DSC of 0.26±0.16 and the largest group (>15 cm <superscript>3</superscript> ) a DSC of 0.63±0.11 (p<0.001). The automated segmentation tended to overestimate compared to the manual reference, both around the actual primary tumor and in false positively classified healthy structures and pathologically enlarged lymph nodes.<br />Conclusion: An automatic segmentation pipeline was evaluated for primary HNSCC on MRI. The MV-CNN produced reasonable segmentation results, especially on large tumors, but overestimation decreased overall performance. In further research, the focus should be on decreasing false positives and make it valuable in treatment planning.<br /> (© 2022. The Author(s).)

Details

Language :
English
ISSN :
1470-7330
Volume :
22
Issue :
1
Database :
MEDLINE
Journal :
Cancer imaging : the official publication of the International Cancer Imaging Society
Publication Type :
Academic Journal
Accession number :
35033188
Full Text :
https://doi.org/10.1186/s40644-022-00445-7