Predictors for early mortality in patients with implantable cardiac defibrillator for heart failure with reduced ejection fraction.
- Source :
-
Indian heart journal [Indian Heart J] 2022 Mar-Apr; Vol. 74 (2), pp. 127-130. Date of Electronic Publication: 2022 Jan 31. - Publication Year :
- 2022
-
Abstract
- Implantable cardioverter defibrillators (ICD) are recommended in heart failure with reduced ejection fraction (HFrEF) patients to reduce arrhythmic deaths. This study aimed to identify risk factors associated with mortality within one-year following the ICD. The data from our hospital's electronic database system was extracted for patients who were implanted ICD secondary to HFrEF between 2009 and 2019. Overall, 1107 patients were included in the present analysis. Mortality rate at one-year following the device implantation was 4.7%. In multivariate analysis; age, atrial fibrillation, New York Heart Association classification >2, blood urea nitrogen, pro-brain natriuretic peptide and albumin independently predicted one year mortality.<br />Competing Interests: Declaration of competing interest All authors declare that they do not have conflict of interest.<br /> (Copyright © 2022 Cardiological Society of India. Published by Elsevier, a division of RELX India, Pvt. Ltd. All rights reserved.)