Evaluation of polarity switching for untargeted lipidomics using liquid chromatography coupled to high resolution mass spectrometry.

Authors :
Carlsson H
Vaivade A
Emami Khoonsari P
Burman J
Kultima K
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2022 Apr 15; Vol. 1195, pp. 123200. Date of Electronic Publication: 2022 Feb 28.
Publication Year :
2022

Abstract

Untargeted lipidomics using liquid chromatography high-resolution mass spectrometry (LC-HRMS) was performed using polarity switching, and in positive and negative polarity separately on the same set of serum samples, and the performances of the methods were evaluated. Polarity switching causes an increase in the cycle time of the HRMS measurements (1.18 s/cycle vs 0.27 s/cycle), resulting in fewer data points across chromatographic peaks. The coefficient of variation (CV) was on average lower for the added isotopically labelled standards in pooled samples (QC) and patient samples using separate polarities (QC = 5.6%, samples = 12.5%) compared to polarity switching (QC = 8.5%, samples = 13.4%), but the difference was not statistically significant. For the endogenous features measured in the QCs polarity switching resulted in on average significantly higher CVs (3.80 (p = 4.25e-30) and 3.3 percentage points (p = 6.84e-40), for positive and negative modes, respectively) however still acceptable for an untargeted method (mean CVs of 17.9% and 12.2% in positive and negative modes respectively). A slightly larger number of endogenous features were detected using the separate polarities, but the large majority of features (>95%) were detected with both methodologies. The overlap of features detected in both positive and negative polarities was low (4.1%) demonstrating the importance of using both polarities for untargeted lipidomics. When investigating the effects of a treatment on multiple sclerosis patients it was found that both methodologies gave highly similar biological results, further confirming the applicability of polarity switching.<br /> (Copyright © 2022 The Authors. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1195
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
35247679
Full Text :
https://doi.org/10.1016/j.jchromb.2022.123200