Back to Search
Start Over
Pacemaker implantation after sutureless or stented valve: results from a controlled randomized trial.
- Source :
-
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2022 Sep 02; Vol. 62 (4). - Publication Year :
- 2022
-
Abstract
- Objectives: Sutureless aortic valves demonstrated non-inferiority to standard stented valves for major cardiovascular and cerebral events at 1 year after aortic valve replacement. We aim to assess the factors correlating with permanent pacemaker implantation (PPI) in both cohorts.<br />Methods: PERSIST-AVR is a prospective, randomized, open-label trial. Patients undergoing aortic valve replacement were randomized to receive a sutureless aortic valve replacement (Su-AVR) or stented sutured bioprosthesis (SAVR). Multivariable analysis was performed to identify possible independent risk factors associated with PPI. A logistic regression analysis was performed to estimate the risk of PPI associated to different valve size.<br />Results: The 2 groups (Su-AVR; n = 450, SAVR n = 446) were well balanced in terms of preoperative risk factors. Early PPI rates were 10.4% in the Su-AVR group and 3.1% in the SAVR. PPI prevalence correlated with valve size XL (P = 0.0119) and preoperative conduction disturbances (P = 0.0079) in the Su-AVR group. No predictors were found in the SAVR cohort. Logistic regression analysis showed a significantly higher risk for PPI with size XL compared to each individual sutureless valve sizes [odds ratio (OR) 0.272 vs size S (95%confidence interval 0.07-0.95), 0.334 vs size M (95% CI 0,16-0; 68), 0.408 vs size L (95% CI 0,21-0.81)] but equivalent risk of PPI rates for all other combination of valve sizes.<br />Conclusions: Su-AVR is associated with higher PPI rate as compared to SAVR. However, the increased PPI rate appears to be size-dependent with significant higher rate only for size XL. The combination of preoperative conduction disorder and a size XL can lead to a higher probability of early PPI in Su-AVR.<br />Clinical Trial Registration Number: NCT02673697.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)
- Subjects :
- Aortic Valve surgery
Humans
Prospective Studies
Prosthesis Design
Risk Factors
Treatment Outcome
Aortic Valve Stenosis etiology
Aortic Valve Stenosis surgery
Bioprosthesis adverse effects
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation adverse effects
Heart Valve Prosthesis Implantation methods
Pacemaker, Artificial adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1873-734X
- Volume :
- 62
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 35290444
- Full Text :
- https://doi.org/10.1093/ejcts/ezac164