Back to Search
Start Over
Real-time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways.
- Source :
-
Magnetic resonance in medicine [Magn Reson Med] 2022 Aug; Vol. 88 (2), pp. 770-786. Date of Electronic Publication: 2022 Apr 10. - Publication Year :
- 2022
-
Abstract
- Purpose: Respiration-related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real-time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions.<br />Methods: A golden-angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans.<br />Results: Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real-time/reference Q <subscript>R</subscript>  = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio Q <subscript>C</subscript>  = 0.46 ± 0.14). Simulations suggest that Q <subscript>C</subscript> can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55-0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48-0.90). Net flow was influenced by respiratory condition (p < 0.01).<br />Conclusions: The presented real-time flow MRI method can quantify respiratory-related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.<br /> (© 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
Details
- Language :
- English
- ISSN :
- 1522-2594
- Volume :
- 88
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Magnetic resonance in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 35403247
- Full Text :
- https://doi.org/10.1002/mrm.29248