Back to Search Start Over

Optimization of Interface Materials between Bi 2 Te 3 -Based Films and Cu Electrodes Enables a High Performance Thin-Film Thermoelectric Cooler.

Authors :
Shen L
Chen Y
Niu B
Liu Z
Qin J
Xie J
Source :
ACS applied materials & interfaces [ACS Appl Mater Interfaces] 2022 May 11; Vol. 14 (18), pp. 21106-21115. Date of Electronic Publication: 2022 Apr 27.
Publication Year :
2022

Abstract

Thermoelectric interface materials (TEiMs) are key to optimizing the electrical contact and stability of the interface between thermoelectric material and metal electrode in high-performance thin-film thermoelectric coolers (TECs). Herein, we explored TEiMs applicable to representative Bi-Te films and found that Cr and Ag are effective TEiMs for p-type Bi <subscript>0.5</subscript> Sb <subscript>1.5</subscript> Te <subscript>3</subscript> and n-type Bi <subscript>2</subscript> Te <subscript>3</subscript> , respectively. By introducing 200 nm Cr and 200 nm Ag as TEiMs for p-type Bi <subscript>0.5</subscript> Sb <subscript>1.5</subscript> Te <subscript>3</subscript> /Cu and n-type Bi <subscript>2</subscript> Te <subscript>3</subscript> /Cu interfaces, Cu diffusion is suppressed, and excellent electrical contact is achieved (1.81 × 10 <superscript>-12</superscript> Ω m <superscript>2</superscript> for p-type and 3.32 × 10 <superscript>-12</superscript> Ω m <superscript>2</superscript> for n-type) and remains stable after heat treatment (2.37 × 10 <superscript>-12</superscript> Ω m <superscript>2</superscript> for p-type and 1.63 × 10 <superscript>-12</superscript> Ω m <superscript>2</superscript> for n-type). Furthermore, the cooling flux of TECs with optimized TEiMs increases from 122.74 to 296.56 W/cm <superscript>2</superscript> , while the performance degradation caused by contact resistance decreases from 50.81 to 4.15%. In addition, our results show that diffusion occurs between not only Cu but also Ag and the thermoelectric material, as TEiMs diffuse slightly. The diffusion of Cu and Ag at the interface can optimize the electrical contact of Bi <subscript>2</subscript> Te <subscript>3</subscript> /Cu but strongly degrade the electrical contacts of Bi <subscript>0.5</subscript> Sb <subscript>1.5</subscript> Te <subscript>3</subscript> /Cu. Our work provides an optimal selection of TEiMs for high-performance Bi-Te thin film coolers and provides guidance for further miniaturization of devices.

Details

Language :
English
ISSN :
1944-8252
Volume :
14
Issue :
18
Database :
MEDLINE
Journal :
ACS applied materials & interfaces
Publication Type :
Academic Journal
Accession number :
35475614
Full Text :
https://doi.org/10.1021/acsami.1c24603