Back to Search
Start Over
A New Flow Cytometry-Based Single Platform for Universal and Differential Serodiagnosis of HTLV-1/2 Infection.
- Source :
-
Frontiers in immunology [Front Immunol] 2022 Apr 14; Vol. 13, pp. 795815. Date of Electronic Publication: 2022 Apr 14 (Print Publication: 2022). - Publication Year :
- 2022
-
Abstract
- In the present work, we developed and evaluated the performance of a new flow cytometry-based single platform, referred to as "FC-Duplex IgG1 (HTLV-1/2)", for universal and differential serodiagnosis of HTLV-1/2 infection. The proposed technology employs a system for detection of IgG1 antibodies in a single competitive immunofluorescence platform by flow cytometry using fluorescently labeled MT-2/MoT cell line mix coupled to a highly sensitive development system (Biotin/Streptavidin/Phycoerythrin). The stability of fluorescent labeling and the antigenicity of MT-2 and MoT cell lines were confirmed upon storage at -20°C for 2, 6, and 12 months. The anti-HTLV-1/2 IgG1 reactivity, expressed as percentage of positive fluorescent cells (PPFC), was evaluated for each target antigen along the titration curve of test serum samples (1:32 to 1:4,096). Upon selection of target cell line and serum dilutions with higher segregation score between groups, the performance of "FIX" and "FIX & PERM" protocols was evaluated. The "FIX" protocol presented excellent performance indices (Se = 92%/Sp = 94%/AUC = 0.96; Se = 96%/Sp = 100%/AUC = 0.99) for the universal (HTLV-1/2 vs. NI) and differential (HTLV-1 vs. HTLV-2) diagnosis of HTLV-1 infection, respectively. Optimization of the "FIX" protocol using the principle of synchronous and asynchronous pairwise analysis further improved the performance of "FC-Duplex IgG1 (HTLV-1/2)", using the "FIX" protocol for differential diagnosis of HTLV-1 and HTLV-2 infections (Se = 100%/Sp = 100%/AUC = 1.00). In conclusion, the "FC-Duplex IgG1 (HTLV-1/2)" method represents an innovation in the biotechnology segment with the potential to compose a serological kit for differential diagnosis of HTLV-1/2 infection for reference laboratories and blood centers.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2022 Pimenta de Paiva, Coelho-dos-Reis, Trindade, Peruhype-Magalhães, Silva Araújo, Gonçalves, Nogueira, Pereira Martins, Lopes Ribeiro, Starling, Alcântara, Ribeiro, Carneiro-Proietti, Sabino, Alves Bicalho, Teixeira-Carvalho and Martins-Filho.)
Details
- Language :
- English
- ISSN :
- 1664-3224
- Volume :
- 13
- Database :
- MEDLINE
- Journal :
- Frontiers in immunology
- Publication Type :
- Academic Journal
- Accession number :
- 35493505
- Full Text :
- https://doi.org/10.3389/fimmu.2022.795815