Sex Disparities in Hemodynamics and Outcomes in Patients Who Underwent Contemporary Transcatheter Aortic Valve Implantation.

Authors :
Medranda GA
Rogers T
Case BC
Zhang C
Shea C
Satler LF
Ben-Dor I
Waksman R
Source :
The American journal of cardiology [Am J Cardiol] 2022 Jul 01; Vol. 174, pp. 101-106. Date of Electronic Publication: 2022 May 09.
Publication Year :
2022

Abstract

Studies have reported worse outcomes after transcatheter aortic valve implantation (TAVI) in women receiving early generation transcatheter heart valves (THVs). They have smaller aortic annuli, which could result in higher gradients and more patient-prosthesis mismatch (PPM) after TAVI. We investigated the interactions between contemporary THV hemodynamics and outcomes in women who underwent TAVI. We conducted a retrospective, observational study of patients who underwent contemporary TAVI from 2015 to 2020. We compared baseline characteristics, in-hospital outcomes, and hemodynamics according to sex. We then dichotomized women according to aortic annular area (<430 or ≥430 mm <superscript>2</superscript> ). Included were 869 patients who underwent TAVI with the SAPIEN 3 or CoreValve Evolut PRO/PRO+. Most patients with small annuli were female (82.5%). They had nonsignificantly higher mortality (30-day: 1.5% vs 0.6%, p = 0.313; 1-year: 4.1% vs 2.7%, p = 0.265). Those who received self-expanding THVs had lower gradients (8.0 mm Hg vs 13.8 mm Hg, p <0.001), resulting in less moderate PPM (21.2% vs 73.6%, p <0.001), similar severe PPM (19.5% vs 15.3%, p = 0.454), and higher rates of pacemaker implantation (14.4% vs 4.2%, p = 0.009). Women with small annuli who received a balloon-expandable THV had nonsignificantly higher mortality (30-day: 2.1% vs 0.8%, p = 0.631; 1-year: 6.3% vs 1.7%, p = 0.118). In conclusion, women who underwent contemporary TAVI had nonsignificantly higher mortality, which could be due to higher PPM rates. These findings were more pronounced in the subset of women with small annuli, in whom those who received self-expanding THVs demonstrated superior hemodynamics at the cost of increased rates of pacemaker implantation.<br />Competing Interests: Disclosures Dr. Rogers is a proctor and consultant at Medtronic and Edwards Lifesciences; is a member of the advisory board of Medtronic; and has equity interest in Transmural Systems. Dr. Waksman is a member of the advisory boards of Abbott Vascular, Boston Scientific, Medtronic, Philips IGT, and Pi-Cardia Ltd.; is a consultant to Abbott Vascular, Biotronik, Boston Scientific, Cordis, Medtronic, Philips IGT, Pi-Cardia Ltd., Swiss Interventional Systems/SIS Medical AG, Transmural Systems Inc., and Venous MedTech; receives grant support from AstraZeneca, Biotronik, Boston Scientific, Chiesi, Medtronic, and Philips IGT; is a member of the speakers bureau of AstraZeneca; and is an investor in MedAlliance and Transmural Systems Inc. The remaining authors have no conflicts of interest to declare.<br /> (Copyright © 2022 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1879-1913
Volume :
174
Database :
MEDLINE
Journal :
The American journal of cardiology
Publication Type :
Academic Journal
Accession number :
35550824
Full Text :
https://doi.org/10.1016/j.amjcard.2022.03.028