Back to Search Start Over

Three-dimensional chemical exchange saturation transfer imaging using compressed SENSE for full z-spectrum acquisition.

Authors :
Wada T
Tokunaga C
Togao O
Hiwatashi A
Kikuchi K
Yoneyama M
Kobayashi K
Kato T
Yoshimoto K
Ishigami K
Yabuuchi H
Source :
Magnetic resonance imaging [Magn Reson Imaging] 2022 Oct; Vol. 92, pp. 58-66. Date of Electronic Publication: 2022 May 28.
Publication Year :
2022

Abstract

Purpose: To evaluate the accuracy of three-dimensional (3D) chemical exchange saturation transfer (CEST) imaging with a compressed sensing (CS) and sensitivity encoding (SENSE) technique (CS-SENSE) for full z-spectrum acquisition.<br />Methods: All images were acquired on 3-T magnetic resonance imaging (MRI) scanner. In the phantom study, we used the acidoCEST imaging. The phantoms were prepared in seven vials containing different concentrations of iopamidol mixed in phosphate-buffered solution with different pH values. The CEST ratios were calculated from the two CEST effects. We compared the CEST ratios obtained with three different 3D CEST imaging protocols (CS-SENSE factor 5, 7, 9) with those obtained with the 2D CEST imaging as a reference standard. In the clinical study, 21 intracranial tumor patients (mean 49.7 ± 17.2 years, 7 males and 14 females) were scanned. We compared the intratumor magnetization transfer ratio asymmetry (MTRasym) obtained with 3D CEST imaging with those obtained with 2D CEST imaging as a reference standard.<br />Results: A smaller CS-SENSE factor resulted in higher agreement and better correlations with the 2D CEST imaging in the phantom study (CS-SENSE 5; ICC = 0.977, R <superscript>2</superscript>  = 0.8943, P < 0.0001: CS-SENSE 7; ICC = 0.970, R <superscript>2</superscript>  = 0.9013, P < 0.0001: CS-SENSE 9; ICC = 0.934, R <superscript>2</superscript>  = 0.8156 P < 0.0001). In the brain tumors, the means and percentile values of MTRasym at 2.0 and 3.5 ppm showed high linear correlations (R <superscript>2</superscript>  = 0.7325-0.8328, P < 0.0001) and high ICCs (0.859-0.907), which enabled successful multi-slice CEST imaging.<br />Conclusions: The 3D CEST imaging with CS-SENSE provided equivalent contrast to 2D CEST imaging; moreover, a z-spectrum with a wide scan range could be obtained.<br /> (Copyright © 2022 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1873-5894
Volume :
92
Database :
MEDLINE
Journal :
Magnetic resonance imaging
Publication Type :
Academic Journal
Accession number :
35640858
Full Text :
https://doi.org/10.1016/j.mri.2022.05.014