Back to Search Start Over

Dual gradient echo in-phase and out of phase sequences in assessment of hepatic iron overload in patients with beta-thalassemia, would be better?

Authors :
Ali Mohamed Aboughonaim A
Naguib Ettaby A
Ibrahim El-Noueum K
Hassab H
Emara DM
Source :
European journal of radiology [Eur J Radiol] 2022 Sep; Vol. 154, pp. 110412. Date of Electronic Publication: 2022 Jun 15.
Publication Year :
2022

Abstract

Purpose: To evaluate the diagnostic accuracy of the dual gradient-echo (GRE) in- and out-of-phase sequences as a quantitative tool for hepatic iron overload in comparison with MRI R2* relaxometry in paediatric patients with beta-thalassemia.<br />Method: Sixty-three patients with beta-thalassemia major (transfusion-dependent) or beta-thalassemia intermedia (transfusion- and non-transfusion-dependent) were referred from the paediatric department (haematology unit) to the radiology department at a university hospital. The paediatrician conducted a clinical examination for the studied group, assessed their laboratory data, conducted R2* relaxometry and dual gradient echo sequences to calculate R2* and relative signal intensity index at the axial mid-section of the liver, and studied their correlation. A 1.5 Tesla MR scanner was used (Achieva; Philips Medical Systems, the Netherlands). Data were fed to the computer and analysed using the IBM SPSS software package version 20.0 (Armonk, NY: IBM Corp). The Kolmogorov-Smirnov test was used to verify the normality of distribution. The significance of the results was determined at the 5% level. The Chi-square, Fisher's exact correction, Pearson coefficient, and Bland-Altman tests were used.<br />Results: Dual gradient-echo in- and out-of-phase sequences using visual assessment accurately assessed 93.65% of our patient group with hepatic iron overload. A significant correlation was found between the relative signal intensity index and hepatic MRI R2* relaxometry (p < 0.001, r = 0.861).<br />Conclusions: Dual gradient-echo in and out-of-phase sequences are good imaging tools for hepatic iron detection and quantification. These sequences showed good correlation with R2* relaxometry (r = 0.861, p < 0.001).<br /> (Copyright © 2022 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1872-7727
Volume :
154
Database :
MEDLINE
Journal :
European journal of radiology
Publication Type :
Academic Journal
Accession number :
35724580
Full Text :
https://doi.org/10.1016/j.ejrad.2022.110412