Back to Search Start Over

A randomized trial of non-fasting vs. fasting for cardiac implantable electronic device procedures (Fast-CIED Study).

Authors :
Bode K
Gerhards M
Doering M
Lucas J
Tijssen J
Dagres N
Hilbert S
Richter S
Nedios S
Lurz J
Moscoso-Luduena C
Arya A
Shamloo AS
Hindricks G
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2022 Oct 13; Vol. 24 (10), pp. 1617-1626.
Publication Year :
2022

Abstract

Aims: Data on safety and efficacy of a non-fasting strategy in minimal invasive cardiac procedures are lacking. We assessed a non-fasting strategy compared with a fasting strategy regarding patient's well-being and safety in elective cardiac implantable electronic device (CIED) procedures.<br />Methods and Results: In this randomized, single-blinded clinical trial, 201 patients (non-fasting = 100, fasting = 101) with a mean age of 72.0 ± 11.6 years (66.7% male) were assigned to a non-fasting strategy (solids/fluids allowed up to 1 h) or a fasting strategy (at least 6 h no solids and 2 h no fluids) before the procedure and analysed on an intention-to-treat basis. The co-primary outcomes were patients' well-being scores (based on numeric rating scale, 0-10) and incidence of intra-procedural food-related adverse events, including vomiting, perioperative pulmonary aspiration, and emergency intubation. Renal, haematological, and metabolic blood parameters and 30-day follow-up data were gathered. The summed pre-procedural patients' well-being score was significantly lower in the non-fasting group [non-fasting: 13.1 ± 9.6 vs. fasting: 16.5 ± 11.4, 95% confidence interval (CI) of mean difference (MD) -6.35 to -0.46, P = 0.029], which was mainly driven by significantly lower scores for hunger and tiredness in the non-fasting group (non-fasting vs. fasting; hunger: 0.9 ± 1.9 vs. 3.1 ± 3.2, 95% CI of MD -2.86 to -1.42, P < 0.001; tiredness: 1.6 ± 2.3 vs. 2.6 ± 2.7, 95% CI of MD -1.68 to -0.29, P = 0.023). No intra-procedural food-related adverse events were observed. Relevant blood parameters and 30-day follow-up did not show significant differences.<br />Conclusion: These results showed that a non-fasting strategy is beneficial to a fasting one regarding patient's well-being and comparable in terms of safety for CIED procedures (NCT04389697).<br />Competing Interests: Conflict of interest: None declared.<br /> (© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved. For permissions, please email: journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1532-2092
Volume :
24
Issue :
10
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
35726877
Full Text :
https://doi.org/10.1093/europace/euac081