Back to Search Start Over

Technical performance of a lateral flow immunoassay for detection of anti-SARS-CoV-2 IgG in the outpatient follow-up of non-severe cases and at different times after vaccination: comparison with enzyme and chemiluminescent immunoassays.

Authors :
Barreira GA
Santos EHD
Pereira MFB
Rodrigues KA
Rocha MC
Kanunfre KA
Marques HHS
Okay TS
Eisencraft AP
Rossi Junior A
Fante AL
Cora AP
Costa Reis AGA
Ferrer APS
Andrade APM
Watanabe A
Gonçalves AMF
Waetge ARP
Silva CA
Ceneviva C
Lazari CDS
Abellan DM
Sabino EC
Bianchini FRM
Alcantara FFP
Ramos GF
Leal GN
Rodriguez IS
Pinho JRR
Carneiro JDA
Paz JA
Ferreira JC
Ferranti JF
Ferreira JOA
Framil JVS
Silva KRD
Bastos KLM
Galleti KV
Cristofani LM
Suzuki L
Campos LMA
Perondi MBM
Diniz MFR
Fonseca MFM
Cordon MNA
Pissolato M
Peres MS
Garanito MP
Imamura M
Dorna MB
Luglio M
Aikawa NE
Degaspare NV
Sakita NK
Udsen NL
Scudeller PG
Gaiolla PVV
Severini RDSG
Rodrigues RM
Toma RK
Paula RIC
Palmeira P
Forsait S
Farhat SCL
Sakano TMS
Koch VHK
Cobello Junior V
Source :
Revista do Instituto de Medicina Tropical de Sao Paulo [Rev Inst Med Trop Sao Paulo] 2022 Jul 13; Vol. 64, pp. e49. Date of Electronic Publication: 2022 Jul 13 (Print Publication: 2022).
Publication Year :
2022

Abstract

This study assessed the technical performance of a rapid lateral flow immunochromatographic assay (LFIA) for the detection of anti-SARS-CoV-2 IgG and compared LFIA results with chemiluminescent immunoassay (CLIA) results and an in-house enzyme immunoassay (EIA). To this end, a total of 216 whole blood or serum samples from three groups were analyzed: the first group was composed of 68 true negative cases corresponding to blood bank donors, healthy young volunteers, and eight pediatric patients diagnosed with other coronavirus infections. The serum samples from these participants were obtained and stored in a pre-COVID-19 period, thus they were not expected to have COVID-19. In the second group of true positive cases, we chose to replace natural cases of COVID-19 by 96 participants who were expected to have produced anti-SARS-CoV-2 IgG antibodies 30-60 days after the vaccine booster dose. The serum samples were collected on the same day that LFIA were tested either by EIA or CLIA. The third study group was composed of 52 participants (12 adults and 40 children) who did or did not have anti-SARS-CoV-2 IgG antibodies due to specific clinical scenarios. The 12 adults had been vaccinated more than seven months before LFIA testing, and the 40 children had non-severe COVID-19 diagnosed using RT-PCR during the acute phase of infection. They were referred for outpatient follow-up and during this period the serum samples were collected and tested by CLIA and LFIA. All tests were performed by the same healthcare operator and there was no variation of LFIA results when tests were performed on finger prick whole blood or serum samples, so that results were grouped for analysis. LFIA's sensitivity in detecting anti-SARS-CoV-2 IgG antibodies was 90%, specificity 97.6%, efficiency 93%, PPV 98.3%, NPV 86.6%, and likelihood ratio for a positive or a negative result were 37.5 and 0.01 respectively. There was a good agreement (Kappa index of 0.677) between LFIA results and serological (EIA or CLIA) results. In conclusion, LFIA analyzed in this study showed a good technical performance and agreement with reference serological assays (EIA or CLIA), therefore it can be recommended for use in the outpatient follow-up of non-severe cases of COVID-19 and to assess anti-SARS-CoV-2 IgG antibody production induced by vaccination and the antibodies decrease over time. However, LFIAs should be confirmed by using reference serological assays whenever possible.

Details

Language :
English
ISSN :
1678-9946
Volume :
64
Database :
MEDLINE
Journal :
Revista do Instituto de Medicina Tropical de Sao Paulo
Publication Type :
Academic Journal
Accession number :
35858039
Full Text :
https://doi.org/10.1590/S1678-9946202264049