Back to Search Start Over

Radiologic-pathologic correlation of lesions in resected liver specimens with an ex vivo MRI-compatible localization device.

Authors :
Rendell VR
Winslow ER
Colgan TJ
Kovacs SK
Mühler MR
Knobloch G
Loeffler AG
Agni RM
Reeder SB
Source :
European radiology [Eur Radiol] 2023 Jan; Vol. 33 (1), pp. 535-544. Date of Electronic Publication: 2022 Jul 21.
Publication Year :
2023

Abstract

Objective: Liver lesion characterization is limited by the lack of an established gold standard for precise correlation of radiologic characteristics with their histologic features. The objective of this study was to demonstrate the feasibility of using an ex vivo MRI-compatible sectioning device for radiologic-pathologic co-localization of lesions in resected liver specimens.<br />Methods: In this prospective feasibility study, adults undergoing curative partial hepatectomy from February 2018 to January 2019 were enrolled. Gadoxetic acid was administered intraoperatively prior to hepatic vascular inflow ligation. Liver specimens were stabilized in an MRI-compatible acrylic lesion localization device (27 × 14 × 14 cm <superscript>3</superscript> ) featuring slicing channels and a silicone gel 3D matrix. High-resolution 3D T1-weighted fast spoiled gradient echo and 3D T2-weighted fast-spin-echo images were acquired using a single channel quadrature head coil. Radiologic lesion coordinates guided pathologic sectioning. A final histopathologic diagnosis was prepared for all lesions. The proportion of successfully co-localized lesions was determined.<br />Results: A total of 57 lesions were identified radiologically and sectioned in liver specimens from 10 participants with liver metastases (n = 8), primary biliary mucinous cystic neoplasm (n = 1), and hepatic adenomatosis (n = 1). Of these, 38 lesions (67%) were < 1 cm. Overall, 52/57 (91%) of radiologically identified lesions were identified pathologically using the device. Of these, 5 lesions (10%) were not initially identified on gross examination but were confirmed histologically using MRI-guided localization. One lesion was identified grossly but not on MRI.<br />Conclusions: We successfully demonstrated the feasibility of a clinical method for image-guided co-localization and histological characterization of liver lesions using an ex vivo MRI-compatible sectioning device.<br />Key Points: • The ex vivo MRI-compatible sectioning device provides a reliable method for radiologic-pathologic correlation of small (< 1 cm) liver lesions in human liver specimens. • The sectioning method can be feasibly implemented within a clinical practice setting and used in future efforts to study liver lesion characterization. • Intraoperative administration of gadoxetic acid results in enhancement in ex vivo MRI images of liver specimens hours later with excellent image quality.<br /> (© 2022. The Author(s), under exclusive licence to European Society of Radiology.)

Details

Language :
English
ISSN :
1432-1084
Volume :
33
Issue :
1
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
35864349
Full Text :
https://doi.org/10.1007/s00330-022-08990-2