Back to Search Start Over

Shear wave elastography as a quantitative biomarker of diabetic peripheral neuropathy: A systematic review and meta-analysis.

Authors :
Dong B
Lyu G
Yang X
Wang H
Chen Y
Source :
Frontiers in public health [Front Public Health] 2022 Jul 22; Vol. 10, pp. 915883. Date of Electronic Publication: 2022 Jul 22 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Diabetic peripheral neuropathy (DPN) is one of the most common chronic complications of diabetes and the strongest initiating risk factor for diabetic foot ulceration. Early diagnosis of DPN through screening measures is, therefore, of great importance for diabetic patients. Recently, shear wave elastography (SWE) has been used as a method that is complementary to neuroelectrophysiological examination in the diagnosis of DPN. We aimed to conduct a meta-analysis based on currently available data to evaluate the performance of tibial nerve stiffness on SWE for diagnosing DPN.<br />Methods: Both PubMed, EMBASE, the Cochrane Library, and Web of Science were searched for studies that investigated the diagnostic performance of SWE for DPN up to March 1th, 2022. Three measures of diagnostic test performance, including the summary area under receiver operating characteristics curve (AUROC), the summary sensitivity and specificity, and the summary diagnostic odds ratios were used to assess the diagnostic accuracy of SWE. All included studies were published between 2017 and 2021.<br />Results: Six eligible studies (with 170 DPN patients, 28 clinically defined DPN patients, 168 non-DPN patients, and 154 control participants) that evaluated tibial nerve stiffness were included for meta-analysis. The summary sensitivity and specificity of SWE for tibial nerve stiffness were 75% (95% confidence interval [CI]: 68-80%) and 86% (95% CI: 80-90%), respectively, and the summary AUROC was 0.84 (95% CI: 0.81-0.87), for diagnosing DPN. A subgroup analysis of five two-dimensional SWE studies revealed similar diagnostic performance, showing the summary sensitivity and specificity of 77% (95% CI: 69-83%) and 86% (95% CI: 79-91%), respectively, and a summary AUROC value of 0.86 (95% CI: 0.83-0.89).<br />Conclusions: SWE is found to have good diagnostic accuracy for detecting DPN and has considerable potential as an important and noninvasive adjunctive tool in the management of patients with DPN.<br /> (Copyright © 2022 Dong, Lyu, Yang, Wang and Chen.)

Details

Language :
English
ISSN :
2296-2565
Volume :
10
Database :
MEDLINE
Journal :
Frontiers in public health
Publication Type :
Report
Accession number :
35937233
Full Text :
https://doi.org/10.3389/fpubh.2022.915883