Back to Search Start Over

Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study.

Authors :
Tokunaga C
Wada T
Togao O
Yamashita Y
Kobayashi K
Kato T
Source :
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine [Magn Reson Med Sci] 2023 Oct 01; Vol. 22 (4), pp. 487-495. Date of Electronic Publication: 2022 Sep 01.
Publication Year :
2023

Abstract

Purpose: Amide proton transfer (APT) imaging may detect changes in tissues' pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values.<br />Methods: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53-7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI <subscript>each saturation pulse</subscript> - APT SI <subscript>shortest or weakest pulse</subscript> )/APT SI <subscript>shortest or weakest pulse</subscript> . The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression.<br />Results: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers.<br />Conclusion: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values.

Details

Language :
English
ISSN :
1880-2206
Volume :
22
Issue :
4
Database :
MEDLINE
Journal :
Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine
Publication Type :
Academic Journal
Accession number :
36047248
Full Text :
https://doi.org/10.2463/mrms.mp.2021-0109