Back to Search
Start Over
The CLOSED protocol to assess optic nerve sheath diameter using color-Doppler: a comparison study in a cohort of idiopathic normal pressure hydrocephalus patients.
- Source :
-
The ultrasound journal [Ultrasound J] 2022 Oct 29; Vol. 14 (1), pp. 43. Date of Electronic Publication: 2022 Oct 29. - Publication Year :
- 2022
-
Abstract
- Background: Sonographic assessment of the optic nerve sheath diameter represents a promising non-invasive technique for estimation of the intracranial pressure. A wide inter-observer variability, along with a lack of a standardized protocol for the optic nerve sheath diameter measurements, could lead to over- or under-estimation. The present study was aimed at evaluating feasibility of color-Doppler for better delineating optic nerve sheath borders, comparing it to B-mode imaging, using the magnetic resonance measurements as a comparison.<br />Methods: Optic nerve sheath diameters were evaluated using magnetic resonance by an expert radiologist in a cohort of patients with suspected idiopathic normal pressure hydrocephalus. Magnetic resonance findings were evaluated twice. In the first half of this cohort, optic nerve sheath diameters were measured using B-mode only, in the second half applying color-Doppler. Measurements obtained using these two techniques were compared to magnetic resonance imaging measurements. The Bland-Altman analysis and concordance correlation coefficient were computed to quantify the strength of agreement between the two magnetic resonance assessments. Box plots and average (± SD) were used to compare assessments by sonographic and magnetic resonance methods.<br />Results: Fifty patients were included. MRI assessment showed a moderate concordance correlation coefficient. Optic nerve sheath diameters measured applying color-Doppler were lower (p < 0.001) and less scattered compared to B-mode assessment, which approached more to magnetic resonance measurements.<br />Conclusions: In this cohort of patients, magnetic resonance showed high intra-rater variability in optic nerve sheath diameter assessments. Optic nerve sheath diameter assessments using color-Doppler yielded lower and less scattered diameters compared to B-mode only.<br /> (© 2022. The Author(s).)
Details
- Language :
- English
- ISSN :
- 2524-8987
- Volume :
- 14
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- The ultrasound journal
- Publication Type :
- Academic Journal
- Accession number :
- 36309606
- Full Text :
- https://doi.org/10.1186/s13089-022-00291-5