Back to Search Start Over

Lesion Index-guided workflow for the treatment of paroxysmal atrial fibrillation is safe and effective - Final results from the LSI Workflow Study.

Authors :
Venkatesh Prasad K
Bonso A
Woods CE
Goya M
Matsuo S
Padanilam BJ
Kreis I
Yang F
Williams CG
Tranter JH
Verbick LZ
Sarver AE
Almendral J
Source :
Heart rhythm O2 [Heart Rhythm O2] 2022 Jun 16; Vol. 3 (5), pp. 526-535. Date of Electronic Publication: 2022 Jun 16 (Print Publication: 2022).
Publication Year :
2022

Abstract

Background: Pulmonary vein isolation (PVI) ablation is a standard therapy for paroxysmal atrial fibrillation (PAF). Lesion Index (LSI) is a metric to guide radiofrequency (RF) ablation using the TactiCath Ablation Catheter, Sensor Enabled with the EnSite Cardiac Mapping System (Abbott).<br />Objective: This study (NCT-03906461) was designed to capture best practices using LSI-guided catheter ablation to treat PAF subjects in a real-world setting.<br />Methods: This prospective single-arm observational study enrolled 143 PAF subjects in the United States, Europe, and Japan undergoing de novo PVI with RF ablation. PVI lesions were assigned to 10 anatomically defined segments. Mean LSIs achieved for all lesions were analyzed. Follow-up was conducted between 3-6 months and 12 months after the procedure.<br />Results: Pulmonary veins were isolated in all subjects. The mean achieved LSI was 4.9, with lower values in Europe (4.4) and Japan (4.5) than the United States (5.5). First-pass success, defined as no gaps requiring touch-up ablation after 20 minutes post isolation, was achieved in 76.2% of subjects. Use of high LSI (≥5) resulted in shorter procedure, RF, and fluoroscopy times and fewer touch-up ablations compared to low LSI (<5). At 12 months, 99.3% of subjects were free from procedure- or device-related serious adverse events and 95.7% (112/117) (35.0% on antiarrhythmic drugs) were free from recurrence and/or a repeat ablation procedure for atrial fibrillation / atrial flutter / atrial tachycardia.<br />Conclusion: LSI-guided ablation strategies proved safe and effective despite differences in LSI workflows. Use of high LSI values resulted in shorter procedure, RF, and fluoroscopy times and fewer touch-up ablations compared to low LSI.<br /> (© 2022 Heart Rhythm Society. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
2666-5018
Volume :
3
Issue :
5
Database :
MEDLINE
Journal :
Heart rhythm O2
Publication Type :
Academic Journal
Accession number :
36340486
Full Text :
https://doi.org/10.1016/j.hroo.2022.06.004