Back to Search Start Over

Hamstring muscle architecture assessed sonographically using wide field of view: A reliability study.

Authors :
Cronin K
Foley S
Cournane S
De Vito G
Delahunt E
Source :
PloS one [PLoS One] 2022 Nov 10; Vol. 17 (11), pp. e0277400. Date of Electronic Publication: 2022 Nov 10 (Print Publication: 2022).
Publication Year :
2022

Abstract

Purpose: To assess the intra-rater reliability of static wide field of view ultrasound to quantify the architectural characteristics of the hamstring muscles.<br />Methods: Twenty amateur male athletes were recruited. Their left hamstring muscles were assessed using static wide field of view ultrasound on two separate occasions. Static ultrasound images were acquired by a single sonographer using a 92mm linear transducer. The architectural characteristics (muscle length, fascicle length, pennation angle and muscle thickness) from two distinct locations of the bicep femoris long head and semimembranosus were evaluated. Muscle length and thickness of the bicep femoris short head and semitendinosus muscle were also evaluated. Intraclass correlation coefficient analyses were performed to determine the intra-rater reliability of the performed measurements.<br />Results: Both muscle (intraclass correlation coefficient = 0.99; standard error of measurement = 4.3 to 6.6mm) and fascicle (intraclass correlation coefficient = 0.92 to 0.98; standard error measurement = 1.1 to 2.4mm) length were measured with excellent intra-rater reliability. Muscle thickness was measured with excellent reliability (intraclass correlation coefficient = 0.9 to 0.96; standard error of measurement = 0.91mm to 1.4mm) for all hamstring muscles except for the proximal segments of the bicep femoris short head (intraclass correlation coefficient = 0.85; standard error of measurement = 0.84mm) and semitendinosus (intraclass correlation coefficient = 0.88; standard error of measurement = 0.82mm), which were measured with good reliability. Pennation angle was measured with good reliability (intraclass correlation coefficient = 0.77 to 0.87; standard error of measurement = 1 to 1.6°).<br />Conclusion: The architectural characteristics of the hamstring muscles of male amateur athletes can be reliably quantified using static wide field of view ultrasound.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2022 Cronin et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
17
Issue :
11
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
36355813
Full Text :
https://doi.org/10.1371/journal.pone.0277400