Back to Search Start Over

Study protocol for Vascular Access outcome measure for function: a vaLidation study In hemoDialysis (VALID) : A multi-center, multinational validation study to assess the accuracy and feasibility of measuring vascular access function in clinical practice.

Authors :
Viecelli AK
Teixeira-Pinto A
Valks A
Baer R
Cherian R
CippĂ  PE
Craig JC
DeSilva R
Jaure A
Johnson DW
Kiriwandeniya C
Kopperschmidt P
Liu WJ
Lee T
Lok C
Madhan K
Mallard AR
Oliver V
Polkinghorne KR
Quinn RR
Reidlinger D
Roberts M
Sautenet B
Hooi LS
Smith R
Snoeijs M
Tordoir J
Vachharajani TJ
Vanholder R
Vergara LA
Wilkie M
Yang B
Yuo TH
Zou L
Hawley CM
Source :
BMC nephrology [BMC Nephrol] 2022 Nov 19; Vol. 23 (1), pp. 372. Date of Electronic Publication: 2022 Nov 19.
Publication Year :
2022

Abstract

Background: A functioning vascular access (VA) is crucial to providing adequate hemodialysis (HD) and considered a critically important outcome by patients and healthcare professionals. A validated, patient-important outcome measure for VA function that can be easily measured in research and practice to harvest reliable and relevant evidence for informing patient-centered HD care is lacking. Vascular Access outcome measure for function: a vaLidation study In hemoDialysis (VALID) aims to assess the accuracy and feasibility of measuring a core outcome for VA function established by the international Standardized Outcomes in Nephrology (SONG) initiative.<br />Methods: VALID is a prospective, multi-center, multinational validation study that will assess the accuracy and feasibility of measuring VA function, defined as the need for interventions to enable and maintain the use of a VA for HD. The primary objective is to determine whether VA function can be measured accurately by clinical staff as part of routine clinical practice (Assessor 1) compared to the reference standard of documented VA procedures collected by a VA expert (Assessor 2) during a 6-month follow-up period. Secondary outcomes include feasibility and acceptability of measuring VA function and the time to, rate of, and type of VA interventions. An estimated 612 participants will be recruited from approximately 10 dialysis units of different size, type (home-, in-center and satellite), governance (private versus public), and location (rural versus urban) across Australia, Canada, Europe, and Malaysia. Validity will be measured by the sensitivity and specificity of the data acquisition process. The sensitivity corresponds to the proportion of correctly identified interventions by Assessor 1, among the interventions identified by Assessor 2 (reference standard). The feasibility of measuring VA function will be assessed by the average data collection time, data completeness, feasibility questionnaires and semi-structured interviews on key feasibility aspects with the assessors.<br />Discussion: Accuracy, acceptability, and feasibility of measuring VA function as part of routine clinical practice are required to facilitate global implementation of this core outcome across all HD trials. Global use of a standardized, patient-centered outcome measure for VA function in HD research will enhance the consistency and relevance of trial evidence to guide patient-centered care.<br />Trial Registration: Clinicaltrials.gov: NCT03969225. Registered on 31st May 2019.<br /> (© 2022. Crown.)

Details

Language :
English
ISSN :
1471-2369
Volume :
23
Issue :
1
Database :
MEDLINE
Journal :
BMC nephrology
Publication Type :
Academic Journal
Accession number :
36402958
Full Text :
https://doi.org/10.1186/s12882-022-02987-1