Back to Search
Start Over
Voltage mapping of Koch's triangle in atrioventricular nodal reentrant tachycardia ablation : Results from an observational multicenter prospective registry.
- Source :
-
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2023 Aug; Vol. 66 (5), pp. 1177-1183. Date of Electronic Publication: 2022 Nov 22. - Publication Year :
- 2023
-
Abstract
- Background: The identification of a "low-voltage bridge" to guide ablation of atrioventricular nodal reentry tachycardia (AVNRT) has been described as a safe and effective strategy in children. We investigated the presence of a low-voltage bridge in adult patients undergoing AVNRT ablation, to evaluate its anatomical correspondence with the successful ablation site. We also investigated the possible correlations between Koch's triangle anatomy and patients' biometric characteristics.<br />Methods: This observational registry prospectively collected data from 200 patients undergoing AVNRT ablation, guided by 3D electroanatomical mapping system, in 6 electrophysiology centers. Koch's triangle voltage map was collected; then, the anatomical correspondence between the low-voltage bridge and the successful ablation site was evaluated. Koch's triangle anatomical dimensions were subsequently drawn from the mapping system and correlated to patients' gender, age, and weight.<br />Results: The low-voltage bridge was identified in 159 over 200 procedures (79.5%). When the low-voltage bridge was identified, its anatomical correspondence with the successful ablation site has been proved in 137 over 159 cases (86%), with a reduction of radiofrequency deployment time. No strict correlations were found, on the other side, between Koch's triangle anatomy and patients' biometric data.<br />Conclusions: The identification of the low-voltage bridge has proved to be a helpful strategy to guide AVNRT ablation in a large cohort of adult patients. Targeting the low-voltage bridge during AVNRT ablation helps to reduce RF application time. Koch's triangle morphological characteristics cannot be predicted on the base of patients' biometric data.<br /> (© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.)
Details
- Language :
- English
- ISSN :
- 1572-8595
- Volume :
- 66
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
- Publication Type :
- Academic Journal
- Accession number :
- 36417122
- Full Text :
- https://doi.org/10.1007/s10840-022-01432-5