Back to Search Start Over

Ab initio calculation based solvent system selection in silico for counter-current chromatography: Separation of resibufogenin glycosylation products.

Authors :
Chen T
Wang Q
Wang Q
La M
Li Y
He L
Zou D
Source :
Journal of chromatography. A [J Chromatogr A] 2022 Dec 20; Vol. 1686, pp. 463649. Date of Electronic Publication: 2022 Nov 14.
Publication Year :
2022

Abstract

In this study, a strategy based on COSMO-RS (Conductor-like Screening Model for Real Solvents) with a constrained optimization calculation was developed for ab initio calculation based solvent system selection in silico for counter-current chromatography. The separation of resibufogenin glycosylation products was selected as an example to show its practicability. The selected solvent system in silico gave the K values consistent with the experimentally measured data (RMSD=0.2861) and the glycosylation products, namely Resibufogenin-3-O-β-D-glucoside (R-G) and Resibufogenin-3-O-β-D-glucosyl (1→2)-β-D-glucoside (R-2G), were successfully separated by HSCCC.<br />Competing Interests: Declaration of Competing Interest We declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2022 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-3778
Volume :
1686
Database :
MEDLINE
Journal :
Journal of chromatography. A
Publication Type :
Academic Journal
Accession number :
36423357
Full Text :
https://doi.org/10.1016/j.chroma.2022.463649