Back to Search Start Over

An Integrated Physical Optimization Framework for Proton Stereotactic Body Radiation Therapy FLASH Treatment Planning Allows Dose, Dose Rate, and Linear Energy Transfer Optimization Using Patient-Specific Ridge Filters.

Authors :
Liu R
Charyyev S
Wahl N
Liu W
Kang M
Zhou J
Yang X
Baltazar F
Palkowitsch M
Higgins K
Dynan W
Bradley J
Lin L
Source :
International journal of radiation oncology, biology, physics [Int J Radiat Oncol Biol Phys] 2023 Jul 15; Vol. 116 (4), pp. 949-959. Date of Electronic Publication: 2023 Feb 01.
Publication Year :
2023

Abstract

Purpose: Patient-specific ridge filters provide a passive means to modulate proton energy to obtain a conformal dose. Here we describe a new framework for optimization of filter design and spot maps to meet the unique demands of ultrahigh-dose-rate (FLASH) radiation therapy. We demonstrate an integrated physical optimization Intensity-modulated proton therapy (IMPT) (IPO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged linear energy transfer (LET <subscript>d</subscript> ).<br />Methods and Materials: We developed an inverse planning software to design patient-specific ridge filters that spread the Bragg peak from a fixed-energy, 250-MeV beam to a proximal beam-specific planning target volume. The software defines patient-specific ridge filter pin shapes and uses a Monte Carlo calculation engine, based on Geant4, to provide dose and LET influence matrices. Plan optimization, using matRAD, accommodates the IPO-IMPT objective function considering dose, dose rate, and LET simultaneously with minimum monitor unit constraints. The framework enables design of both regularly spaced and sparse-optimized ridge filters, from which some pins are omitted to allow faster delivery and selective LET optimization. To demonstrate the framework, we designed ridge filters for 3 example patients with lung cancer and optimized the plans using IPO-IMPT.<br />Results: The IPO-IMPT framework selectively spared the organs at risk by reducing LET and increasing dose rate, relative to IMPT planning. Sparse-optimized ridge filters were superior to regularly spaced ridge filters in dose rate. Depending on which parameter is prioritized, volume distributions and histograms for dose, DADR, and LET <subscript>d</subscript> , using evaluation structures specific to heart, lung, and esophagus, show high levels of FLASH dose-rate coverage and/or reduced LET <subscript>d</subscript> , while maintaining dose coverage within the beam specific planning target volume.<br />Conclusions: This proof-of-concept study demonstrates the feasibility of using an IPO-IMPT framework to accomplish proton FLASH stereotactic body proton therapy, accounting for dose, DADR, and LET <subscript>d</subscript> simultaneously.<br /> (Copyright © 2023. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1879-355X
Volume :
116
Issue :
4
Database :
MEDLINE
Journal :
International journal of radiation oncology, biology, physics
Publication Type :
Academic Journal
Accession number :
36736634
Full Text :
https://doi.org/10.1016/j.ijrobp.2023.01.048