Safety and Efficacy of the Passeo-18 Lux Drug-Coated Balloon Catheter in Atherosclerotic Femoropopliteal Lesions: The Multicenter BIOLUX P-IV China Study.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2023 Jul; Vol. 93, pp. 275-282. Date of Electronic Publication: 2023 Feb 14. - Publication Year :
- 2023
-
Abstract
- Background: The purpose of this trial was to assess the safety and effectiveness of a paclitaxel-coated balloon catheter in Chinese patients with de novo or nonstented restenotic femoropopliteal atherosclerotic lesions.<br />Methods: BIOLUX P-IV China is a prospective, independently adjudicated, multicenter, single-arm trial conducted in China. Patients with Rutherford class 2-4 were eligible, excluded were patients in which predilation resulted in severe (≥ grade D) flow-limiting dissection or residual stenosis > 70%. Follow-up assessments were conducted at 1, 6, and 12 months. The primary safety end point was 30-day major adverse event rate and the primary effectiveness end point was primary patency at 12 months.<br />Results: We enrolled 158 patients with 158 lesions. Mean age was 67.6 ± 9.6 years, diabetes was present in 53.8% (n = 85), and previous peripheral intervention/surgeries in 17.1% (n = 27). Lesions were 4.1 ± 0.9 mm in diameter and 74 ± 50 mm long with a mean diameter stenosis of 91 ± 13%; 58.2% (n = 92) were occluded (core laboratory analysis). Device success was achieved in all patients. The rate of major adverse events was 0.6% (95% confidence interval: 0.0; 3.5) at 30 days, consisting of 1 target lesion revascularization. At 12 months, binary restenosis was present in 18.7% (n = 26) and target lesion revascularization was performed in 1.4% (n = 2, all clinically driven), resulting in a primary patency of 80.0% (95% confidence interval: 72.4, 85.8); no major target limb amputation occurred. Clinical improvement at 12 months, defined as improvement of at least 1 Rutherford class, was 95.3% (n = 130). The median walking distance per 6-minute walk test was 279 m at baseline and improved by 50 m at 30 days and by 60 m at 12 months; the visual analogue scale changed from 76.6 ± 15.6 at baseline to 80.0 ± 15.0 at 30 days and 78.6 ± 14.6 at 12 months.<br />Conclusions: Our results confirmed the clinical effectiveness and safety of a paclitaxel-coated peripheral balloon dilatation catheter for the treatment of de novo and nonstented restenotic lesion of the superficial femoral and proximal popliteal artery in Chinese patients (NCT02912715).<br /> (Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Humans
Middle Aged
Aged
Prospective Studies
Constriction, Pathologic etiology
Treatment Outcome
Limb Salvage
Femoral Artery diagnostic imaging
Popliteal Artery diagnostic imaging
Paclitaxel adverse effects
China
Coated Materials, Biocompatible
Catheters
Vascular Patency
Peripheral Arterial Disease diagnostic imaging
Peripheral Arterial Disease therapy
Atherosclerosis etiology
Angioplasty, Balloon adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 93
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 36796585
- Full Text :
- https://doi.org/10.1016/j.avsg.2023.01.040