Back to Search Start Over

Contact force and catheter stability are predictive metrics of successful pulmonary vein isolation with high-power short duration ablation in atrial fibrillation.

Authors :
Honarbakhsh S
Martin CA
Dhillon G
Gallagher M
Sohal M
Chow A
Ahsan S
Abbass H
Whittaker-Axon S
Lambiase PD
Davies MJ
Ginks M
Hunter RJ
Source :
Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2023 May; Vol. 34 (5), pp. 1141-1151. Date of Electronic Publication: 2023 Apr 20.
Publication Year :
2023

Abstract

Introduction: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter.<br />Methods and Results: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort.<br />Conclusions: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.<br /> (© 2023 Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1540-8167
Volume :
34
Issue :
5
Database :
MEDLINE
Journal :
Journal of cardiovascular electrophysiology
Publication Type :
Academic Journal
Accession number :
36808788
Full Text :
https://doi.org/10.1111/jce.15867