Back to Search Start Over

Ultrashort echo time magnetization transfer imaging of knee cartilage and meniscus after long-distance running.

Authors :
Zhu D
Wu W
Yu W
Hong G
Fang Y
Li S
Ma Y
Source :
European radiology [Eur Radiol] 2023 Jul; Vol. 33 (7), pp. 4842-4854. Date of Electronic Publication: 2023 Feb 23.
Publication Year :
2023

Abstract

Objective: To assess the detection of changes in knee cartilage and meniscus of amateur marathon runners before and after long-distance running using a 3D ultrashort echo time MRI sequence with magnetization transfer preparation (UTE-MT).<br />Methods: We recruited 23 amateur marathon runners (46 knees) in this prospective cohort study. MRI scans using UTE-MT and UTE-T2* sequences were performed pre-race, 2 days post-race, and 4 weeks post-race. UTE-MT ratio (UTE-MTR) and UTE-T2* were measured for knee cartilage (eight subregions) and meniscus (four subregions). The sequence reproducibility and inter-rater reliability were also investigated.<br />Results: Both the UTE-MTR and UTE-T2* measurements showed good reproducibility and inter-rater reliability. For most subregions of cartilage and meniscus, the UTE-MTR values decreased 2 days post-race and increased after 4 weeks of rest. Conversely, the UTE-T2* values increased 2 days post-race and decreased after 4 weeks. The UTE-MTR values in lateral tibial plateau, central medial femoral condyle, and medial tibial plateau showed a significant decrease at 2 days post-race compared to the other two time points (p < 0.05). By comparison, no significant UTE-T2* changes were found for any cartilage subregions. For meniscus, the UTE-MTR values in medial posterior horn and lateral posterior horn regions at 2 days post-race were significantly lower than those at pre-race and 4 weeks post-race (p < 0.05). By comparison, only the UTE-T2* values in medial posterior horn showed a significant difference.<br />Conclusions: UTE-MTR is a promising method for the detection of dynamic changes in knee cartilage and meniscus after long-distance running.<br />Key Points: • Long-distance running causes changes in the knee cartilage and meniscus. • UTE-MT monitors dynamic changes of knee cartilage and meniscal non-invasively. • UTE-MT is superior to UTE-T2* in monitoring dynamic changes in knee cartilage and meniscus.<br /> (© 2023. The Author(s), under exclusive licence to European Society of Radiology.)

Details

Language :
English
ISSN :
1432-1084
Volume :
33
Issue :
7
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
36814033
Full Text :
https://doi.org/10.1007/s00330-023-09462-x