Back to Search Start Over

Impact of implant metal type and vancomycin prophylaxis on postoperative spine infection: an in-vivo study.

Authors :
Gupta S
Maitra S
Farooqi AS
Gupta K
Wetpiriyakul P
Pereira M
Durbin-Johnson B
Gupta MC
Source :
Spine deformity [Spine Deform] 2023 Jul; Vol. 11 (4), pp. 815-823. Date of Electronic Publication: 2023 Mar 15.
Publication Year :
2023

Abstract

Purpose: To evaluate the effectiveness of vancomycin prophylaxis on spinal implant metal types.<br />Methods: 42 rabbits underwent posterior, single-level instrumentation at L5-L6 with stainless steel (n = 18), cobalt chrome (n = 12), or titanium (n = 12) wire. All implants were inoculated with 1 × 10 <superscript>6</superscript> colony forming units (CFU) of methicillin-resistant S. Aureus (MRSA). In the intrawound vancomycin subgroup (n = 18, 6 from each metal type), 40 mg of vancomycin powder was placed in the wound. In the IV vancomycin subgroup (n = 6, all stainless steel), 15 mg/kg of IV vancomycin was given preoperatively. Local soft tissue and implants were harvested 1-week postoperatively and separately cultured.<br />Results: Intrawound vancomycin significantly reduced the rate of soft tissue infection (44.4% vs 100%) and implant infection (27.8% vs 100%) (p < 0.001). Within the intrawound vancomycin subgroup, cobalt chrome implants were associated with higher median soft tissue MRSA growth (130 CFU) than stainless steel (0 CFU) or titanium (0 CFU) (p = 0.02). Cobalt chrome implants were also more likely to develop soft tissue MRSA infection (83.3%) as compared to stainless steel (16.7%) or titanium (33.3%) (p = 0.04). Median soft tissue MRSA growth among stainless steel implants without prophylaxis, with IV vancomycin, and with vancomycin powder was 1.18 × 10 <superscript>7</superscript> , 195, and 0 CFU, respectively. The rate of soft tissue MRSA infection without prophylaxis, with IV vancomycin, and with vancomycin powder was 100, 66.7, and 16.7%, respectively (p = 0.015).<br />Conclusion: Intrawound vancomycin is more effective than IV vancomycin and effectively reduces the risk of infection, but is less effective in cobalt chrome implants due to residual soft tissue infection.<br /> (© 2023. The Author(s), under exclusive licence to Scoliosis Research Society.)

Details

Language :
English
ISSN :
2212-1358
Volume :
11
Issue :
4
Database :
MEDLINE
Journal :
Spine deformity
Publication Type :
Academic Journal
Accession number :
36920741
Full Text :
https://doi.org/10.1007/s43390-023-00674-1