Back to Search Start Over

Non-invasive hemodynamic diagnosis based on non-linear pulse wave theory applied to four limbs.

Authors :
Song X
Liu Y
Wang S
Zhang H
Qiao A
Wang X
Source :
Frontiers in bioengineering and biotechnology [Front Bioeng Biotechnol] 2023 Mar 09; Vol. 11, pp. 1081447. Date of Electronic Publication: 2023 Mar 09 (Print Publication: 2023).
Publication Year :
2023

Abstract

Introduction: Hemodynamic diagnosis indexes (HDIs) can comprehensively evaluate the health status of the cardiovascular system (CVS), particularly for people older than 50 years and prone to cardiovascular disease (CVDs). However, the accuracy of non-invasive detection remains unsatisfactory. We propose a non-invasive HDIs model based on the non-linear pulse wave theory (NonPWT) applied to four limbs. Methods: This algorithm establishes mathematical models, including pulse wave velocity and pressure information of the brachial and ankle arteries, pressure gradient, and blood flow. Blood flow is key to calculating HDIs. Herein, we derive blood flow equation for different times of the cardiac cycle considering the four different distributions of blood pressure and pulse wave of four limbs, then obtain the average blood flow in a cardiac cycle, and finally calculate the HDIs. Results: The results of the blood flow calculations reveal that the average blood flow in the upper extremity arteries is 10.78 ml/s (clinically: 2.5-12.67 ml/s), and the blood flow in the lower extremity arteries is higher than that in the upper extremity. To verify model accuracy, the consistency between the clinical and calculated values is verified with no statistically significant differences ( p < 0.05). Model IV or higher-order fitting is the closest. To verify the model generalizability, considering the risk factors of cardiovascular diseases, the HDIs are recalculated using model IV, and thus, consistency is verified ( p < 0.05 and Bland-Altman plot). Conclusion: We conclude our proposed algorithmic model based on NonPWT can facilitate the non-invasive hemodynamic diagnosis with simpler operational procedures and reduced medical costs.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Song, Liu, Wang, Zhang, Qiao and Wang.)

Details

Language :
English
ISSN :
2296-4185
Volume :
11
Database :
MEDLINE
Journal :
Frontiers in bioengineering and biotechnology
Publication Type :
Academic Journal
Accession number :
36970627
Full Text :
https://doi.org/10.3389/fbioe.2023.1081447