Back to Search Start Over

Clinician Experiences With Hybrid Closed Loop Insulin Delivery Systems in Veterans With Type 1 Diabetes: Qualitative Study.

Authors :
Mizokami-Stout K
Thompson HM
Hurren K
Leone V
Piatt GA
Lee JM
Pop-Busui R
DeJonckheere M
Source :
JMIR diabetes [JMIR Diabetes] 2023 Mar 29; Vol. 8, pp. e45241. Date of Electronic Publication: 2023 Mar 29.
Publication Year :
2023

Abstract

Background: Hybrid closed loop (HCL) insulin pumps adjust insulin delivery based on input from a continuous glucose monitor. Several systems are FDA approved and associated with improved time in range, reduction in hemoglobin A <subscript>1c</subscript> , and decreased incidence of hypoglycemia. Major diabetes guidelines differ in their strength of recommendations regarding the use of HCL systems. Overall, limited information about the factors that influence HCL pump clinical decision-making is available, especially among endocrinology clinicians.<br />Objective: The study objective is to describe the knowledge and attitudes, network support, and self-efficacy regarding HCL insulin delivery systems among endocrinology clinicians in one Veterans Affairs (VA) Healthcare System in the Midwest.<br />Methods: Following a descriptive approach, this qualitative study used semistructured interviews and inductive thematic analysis. All endocrinologists, endocrinology fellows, and nurses in the endocrinology and metabolism department at one VA Healthcare System in the Midwest were invited to participate in one-on-one phone interviews. Thematic analysis explored clinician perspectives on HCL insulin pump systems.<br />Results: Participants (n=11) had experience within VA and university health care system endocrinology clinics. From their experiences, 4 themes were identified involving the evaluation and assessment of insulin pump candidates, prescribing challenges, clinical benefits of HCL pumps, and overall clinician confidence.<br />Conclusions: Findings suggest that clinicians believe HCL systems have significant glycemic benefits but are not appropriate for all patients, especially those with cognitive impairment. HCL pump initiation is a multi-step process requiring an interdisciplinary team of health care clinicians to ensure patient and pump success. Furthermore, HCL systems improve clinician confidence in overall diabetes management.<br /> (©Kara Mizokami-Stout, Holly M Thompson, Kathryn Hurren, Virginia Leone, Gretchen A Piatt, Joyce M Lee, Rodica Pop-Busui, Melissa DeJonckheere. Originally published in JMIR Diabetes (https://diabetes.jmir.org), 29.03.2023.)

Details

Language :
English
ISSN :
2371-4379
Volume :
8
Database :
MEDLINE
Journal :
JMIR diabetes
Publication Type :
Academic Journal
Accession number :
36989019
Full Text :
https://doi.org/10.2196/45241