Back to Search Start Over

Reliability of the five times sit to stand test performed remotely by multiple sclerosis patients.

Authors :
Dos Santos FC
Candotti CT
Rodrigues LP
Source :
Multiple sclerosis and related disorders [Mult Scler Relat Disord] 2023 May; Vol. 73, pp. 104654. Date of Electronic Publication: 2023 Mar 28.
Publication Year :
2023

Abstract

Introduction: Multiple Sclerosis, known main cause of non-traumatic neurological disability in adults, leads to changes in muscle strength, especially in the lower limbs. Assessing muscle strength in these patients is thus essential and can be achieved by the Five Times Sit to Stand Test (FTSST), commonly performed in person. Due to the COVID-19 pandemic and social distancing measured adopted, Brazilian physiotherapists turned to remote monitoring and assessment, supported by Resolution n° 516/2020, which required proving the reliability of tests. Given this scenario, this study sought to evaluate the intra- and inter-rater reliability of the Five Times Sit to Stand Test performed remotely and synchronously by multiple sclerosis patients.<br />Methods: A sample of 33 individuals with relapsing-remitting Multiple Sclerosis (18 women and 15 men, mean age 43.7 ± 13.4 years) were remotely and synchronously by video call. Inter-rater reliability was evaluated by analyzing FTSST execution time, in seconds, timed by two different raters on the same video call. In turn, intra-rater reliability was assessed by analyzing the execution time recorded in two different video calls made by the same rater, within a 24-28-h interval. Descriptive and inferential data analysis were performed using SPSS 20.0 software. Means and standard deviation were calculated for descriptive statistic. Intraclass correlation coefficient (ICC), with a 0.05 significance level, standard error of measurement (SEM) and minimal detectable change (MDC) were calculated for inferential analysis.<br />Results: Data analysis showed excellent ICC values and low SEM and MDC values regarding inter-rater reliability (ICC: 0.993 (0.986-0.996); p-value: <0.001; SEM: 0.6 s; MDC: 1.6 s) and intra-rater reliability (ICC: 0.962 (0.925-0.981); p-value: <0.001; SEM: 1.4 s; MDC: 3.8 s).<br />Conclusion: Based on these values, FTSST performed remotely and synchronously by relapsing-remitting Multiple Sclerosis patients is reliable and can be used both by different raters, for assessment, or by the same rater, in pre- and post-test situations.<br />Competing Interests: Declaration of Competing Interest None.<br /> (Copyright © 2023 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
2211-0356
Volume :
73
Database :
MEDLINE
Journal :
Multiple sclerosis and related disorders
Publication Type :
Academic Journal
Accession number :
37060677
Full Text :
https://doi.org/10.1016/j.msard.2023.104654