Back to Search Start Over

Deep phenotyping of PROM1-associated retinal degeneration.

Authors :
Schließleder G
Kalitzeos A
Kasilian M
Singh N
Wang Z
Hu Z
Großpötzl M
Sadda S
Wedrich A
Michaelides M
Strauss RW
Source :
The British journal of ophthalmology [Br J Ophthalmol] 2024 Mar 20; Vol. 108 (4), pp. 558-565. Date of Electronic Publication: 2024 Mar 20.
Publication Year :
2024

Abstract

Background/aims: The purpose of this study was to investigate retinal structure in detail of subjects with autosomal-dominant (AD) and autosomal-recessive (AR) PROM1 -associated retinal degeneration ( PROM1 -RD), study design: institutional, cross-sectional study.<br />Methods: Four eyes from four subjects (three with AD and one with AR) PROM1 -RD were investigated by ophthalmic examination including best-corrected visual acuity (BCVA) and multimodal retinal imaging: fundus autofluorescence (FAF), spectral-domain optical coherence tomography (SD-OCT) and adaptive optics scanning light ophthalmoscopy. Quantitative assessment of atrophic lesions determined by FAF, thickness of individual retinal layers and cone photoreceptor quantification was performed.<br />Results: BCVA ranged from 20/16 to 20/200. Initial pathological changes included the presence of hyperautofluorescent spots on FAF imaging, while later stages demonstrated discrete areas of atrophy. In all patients, thinning of the outer retinal layers on SD-OCT with varying degrees of atrophy could be detected depending on disease-causing variants and age. Cone density was quantified both in central and/or at different eccentricities from the fovea. Longitudinal assessments were possible in two patients.<br />Conclusions: PROM1 -RD comprises a wide range of clinical phenotypes. Depending on the stage of disease, the cone mosaic in PROM1 -RD is relatively preserved and can potentially be targeted by cone-directed interventions.<br />Competing Interests: Competing interests: SS serves as a consultant for Amgen, Apellis, Alnylam, Pfizer, Abbvie/Allergan, Roche/Genentech, Novartis, Regeneron, 4DMT, Oxurion, Gyroscope, Nanoscope, Heidelberg, Optos, and Centervue. He has received speaker fees from Heidelberg, Carl Zeiss Meditec, Nidek, Topcon, Optos, and Novartis. He has received research instruments from Heidelberg, Carl Zeiss Meditec, Nidek, Topcon, Optos and Centervue.<br /> (© Author(s) (or their employer(s)) 2024. No commercial re-use. See rights and permissions. Published by BMJ.)

Details

Language :
English
ISSN :
1468-2079
Volume :
108
Issue :
4
Database :
MEDLINE
Journal :
The British journal of ophthalmology
Publication Type :
Academic Journal
Accession number :
37080590
Full Text :
https://doi.org/10.1136/bjo-2022-322036