Back to Search Start Over

Extension of matRad with a modified microdosimetric kinetic model for carbon ion treatment planning: Comparison with Monte Carlo calculation.

Authors :
Yoon E
Kim JI
Park JM
Choi CH
Jung S
Source :
Medical physics [Med Phys] 2023 Sep; Vol. 50 (9), pp. 5884-5896. Date of Electronic Publication: 2023 May 10.
Publication Year :
2023

Abstract

Background: Treatment planning is essential for in silico particle therapy studies. matRad is an open-source research treatment planning system (TPS) based on the local effect model, which is a type of relative biological effectiveness (RBE) model.<br />Purpose: This study aims to implement a microdosimetric kinetic model (MKM) in matRad and develop an automation algorithm for Monte Carlo (MC) dose recalculation using the TOPAS code. In addition, we provide the developed MKM extension as open-source tool for users.<br />Methods: Carbon beam data were generated using TOPAS MC pencil beam irradiation. We parameterized the TOPAS MC beam data with a double-Gaussian fit and modeled the integral depth doses and lateral spot profiles in the range of 100-430 MeV/u. To implement the MKM, the specific energy data table for Z = 1-6 and integrated depth-specific energy data were acquired based on the Kiefer-Chatterjee track structure and TOPAS MC simulation, respectively. Generic data were integrated into matRad, and treatment planning was performed based on these data. The optimized plan parameters were automatically converted into MC simulation input. Finally, the matRad TPS and TOPAS MC simulations were compared using the RBE-weighted dose calculation results. A comparison was made for three geometries: homogeneous water phantom, inhomogeneous phantom, and patient.<br />Results: The RBE-weighted dose (D <subscript>RBE</subscript> ) distribution agreed with TOPAS MC within 1.8% for all target sizes for the homogeneous phantom. For the inhomogeneous phantom, the relative difference in the range of 80% of the prescription dose in the distal fall-off region (R80) between the matRad TPS and TOPAS MC was 0.6% (1.1 mm). D <subscript>RBE</subscript> between the TPS and the MC was within 4.0%. In the patient case, the difference in the dose-volume histogram parameters for the target volume between the TPS and the MC was less than 2.7%. The relative difference in R80 was 0.7% (1.2 mm).<br />Conclusions: The MKM was successfully implemented in matRad TPS, and the RBE-weighted dose was comparable to that of TOPAS MC. The MKM-implemented matRad was released as an open-source tool. Further investigations with MC simulations can be conducted using this tool, providing a good option for carbon ion research.<br /> (© 2023 American Association of Physicists in Medicine.)

Details

Language :
English
ISSN :
2473-4209
Volume :
50
Issue :
9
Database :
MEDLINE
Journal :
Medical physics
Publication Type :
Academic Journal
Accession number :
37162309
Full Text :
https://doi.org/10.1002/mp.16449