Back to Search
Start Over
Modification of the Warden Procedure for Surgical Repair of Partial Anomalous Pulmonary Venous Connection.
- Source :
-
World journal for pediatric & congenital heart surgery [World J Pediatr Congenit Heart Surg] 2023 Jul; Vol. 14 (4), pp. 497-499. Date of Electronic Publication: 2023 May 15. - Publication Year :
- 2023
-
Abstract
- Warden procedure is a popular technique for repairing partial anomalous pulmonary venous connection. We describe a modification of this technique for surgical repair of this condition by raising both a superior vena cava (SVC) flap and right atrial appendage flap to create a tension-free SVC-RA continuity (neo-SVC). The anomalous pulmonary veins are routed via the remanent of proximal SVC and baffled to the left atrium across a surgically created or enlarged atrial septal defect using autologous pericardium.
Details
- Language :
- English
- ISSN :
- 2150-136X
- Volume :
- 14
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- World journal for pediatric & congenital heart surgery
- Publication Type :
- Academic Journal
- Accession number :
- 37186786
- Full Text :
- https://doi.org/10.1177/21501351231168830