Fast and sensitive coulometric signal transduction for ion-selective electrodes by utilizing a two-compartment cell.
- Source :
-
Talanta [Talanta] 2023 Sep 01; Vol. 262, pp. 124623. Date of Electronic Publication: 2023 May 05. - Publication Year :
- 2023
-
Abstract
- Here, we propose a fast and sensitive coulometric signal transduction method for ion-selective electrodes (ISEs) by utilizing a two-compartment cell. A potassium ion-selective electrode (K <superscript>+</superscript> -ISE) was connected as reference electrode (RE) and placed in the sample compartment. A glassy carbon (GC) electrode coated with poly(3,4-ethylenedioxythiophene) (GC/PEDOT), or reduced graphene oxide (GC/RGO), was connected as working electrode (WE) and placed in the detection compartment together with a counter electrode (CE). The two compartments were connected with an Ag/AgCl wire. The measured cumulated charge was amplified by increasing the capacitance of the WE. The observed slope of the cumulated charge with respect to the change of the logarithm of the K <superscript>+</superscript> ion activity was linearly proportional to the capacitance of the GC/PEDOT and GC/RGO, estimated from impedance spectra. Furthermore, the sensitivity of the coulometric signal transduction using a commercial K <superscript>+</superscript> -ISE with internal filling solution as RE and GC/RGO as WE allowed to decrease the response time while still being able to detect a 0.2% change in K <superscript>+</superscript> concentration. The coulometric method utilizing a two-compartment cell was found to be feasible for the determination of K <superscript>+</superscript> concentrations in serum. The advantage of this two-compartment approach, compared to the coulometric transduction described earlier, was that no current passed through the K <superscript>+</superscript> -ISE that was connected as RE. Therefore, current-induced polarization of the K <superscript>+</superscript> -ISE was avoided. Furthermore, since the GCE/PEDOT and GCE/RGO (used as WE) had a low impedance, the response time of the coulometric response decreased from minutes to seconds.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2023 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-3573
- Volume :
- 262
- Database :
- MEDLINE
- Journal :
- Talanta
- Publication Type :
- Academic Journal
- Accession number :
- 37244238
- Full Text :
- https://doi.org/10.1016/j.talanta.2023.124623