Back to Search
Start Over
Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits.
- Source :
-
Diagnostic and interventional imaging [Diagn Interv Imaging] 2023 Oct; Vol. 104 (10), pp. 490-499. Date of Electronic Publication: 2023 May 27. - Publication Year :
- 2023
-
Abstract
- Purpose: The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits.<br />Materials and Methods: Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality.<br />Results: In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 ± 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 ± 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4).<br />Conclusion: With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.<br />Competing Interests: Declaration of Competing Interest Yoad Yagil PhD, Elias Lahoud PhD, Klaus Erhard PhD, Bernhard Brendel PhD and Philippe Coulon PhD are employees of Philips Healthcare.<br /> (Copyright © 2023. Published by Elsevier Masson SAS.)
Details
- Language :
- English
- ISSN :
- 2211-5684
- Volume :
- 104
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- Diagnostic and interventional imaging
- Publication Type :
- Academic Journal
- Accession number :
- 37248095
- Full Text :
- https://doi.org/10.1016/j.diii.2023.05.002