Back to Search Start Over

Mobile and wearable technologies for the analysis of Ten Meter Walk Test: A concise systematic review.

Authors :
Gabriel CL
Pires IM
Coelho PJ
Zdravevski E
Lameski P
Mewada H
Madeira F
Garcia NM
Carreto C
Source :
Heliyon [Heliyon] 2023 May 25; Vol. 9 (6), pp. e16599. Date of Electronic Publication: 2023 May 25 (Print Publication: 2023).
Publication Year :
2023

Abstract

Physical issues started to receive more attention due to the sedentary lifestyle prevalent in modern culture. The Ten Meter Walk Test allows measuring the person's capacity to walk along 10 m and analyzing the advancement of various medical procedures for ailments, including stroke. This systematic review is related to the use of mobile or wearable devices to measure physical parameters while administering the Ten Meter Walk Test for the analysis of the performance of the test. We applied the PRISMA methodology for searching the papers related to the Ten Meter Walk Test. Natural Language Processing (NLP) algorithms were used to automate the screening process. Various papers published in two decades from multiple scientific databases, including IEEE Xplore, Elsevier, Springer, EMBASE, SCOPUS, Multidisciplinary Digital Publishing Institute (MDPI), and PubMed Central were analyzed, focusing on various diseases, devices, features, and methods. The study reveals that chronometer and accelerometer sensors measuring spatiotemporal features are the most pertinent in the Gait characterization of most diseases. Likewise, all studies emphasized the close relation between the quality of the sensor's data obtained and the system's ultimate accuracy. In other words, calibration procedures are needed because of the body part where the sensor is worn and the type of sensor. In addition, using ambient sensors providing kinematic and kinetic features in conjunction with wearable sensors and consistently acquiring walking signals can enhance the system's performance. The most common weaknesses in the analyzed studies are the sample size and the unavailability of continuous monitoring devices for measuring the Ten Meter Walk Test.<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper<br /> (© 2023 The Authors.)

Details

Language :
English
ISSN :
2405-8440
Volume :
9
Issue :
6
Database :
MEDLINE
Journal :
Heliyon
Publication Type :
Academic Journal
Accession number :
37274667
Full Text :
https://doi.org/10.1016/j.heliyon.2023.e16599