Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and postoperative parameters.
- Source :
-
Journal of shoulder and elbow surgery [J Shoulder Elbow Surg] 2023 Dec; Vol. 32 (12), pp. e587-e596. Date of Electronic Publication: 2023 Jun 03. - Publication Year :
- 2023
-
Abstract
- Background: Navigated augmented reality (AR) through a head-mounted display (HMD) may lead to accurate glenoid component placement in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the deviation between planned, intra- and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement assisted by a navigated AR through HMD during RSA.<br />Methods: Both shoulders of 6 fresh frozen human cadavers, free from fractures or other bony pathologies, were used. Preoperative computed tomography (CT) scans were used for the 3-dimensional (3D) planning. The glenoid component placement was assisted using a navigated AR system through an HMD in all specimens. Intraoperative inclination, retroversion, depth, and rotation were measured by the system. A postoperative CT scan was performed. The pre- and postoperative 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postoperative inclination, retroversion, entry point, depth, and rotation of the glenoid component placement. Additionally, a comparison between intra- and postoperative values was calculated. Outliers were defined as >10° inclination, >10° retroversion, >3 mm entry point.<br />Results: The registration algorithm of the scapulae prior to the procedure was correctly completed for all cases. The deviations between planned and postoperative values were 1.0° ± 0.7° for inclination, 1.8° ± 1.3° for retroversion, 1.1 ± 0.4 mm for entry point, 0.7 ± 0.6 mm for depth, and 1.7° ± 1.6° for rotation. The deviation between intra- and postoperative values were 0.9° ± 0.8° for inclination, 1.2° ± 1.1° for retroversion, 0.6 ± 0.5 mm for depth, and 0.3° ± 0.2° for rotation. There were no outliers between planned and postoperative parameters.<br />Conclusion: In this study, the use of a navigated AR system through an HMD for RSA led to low deviation between planned and postoperative values and between intra- and postoperative parameters.<br /> (Copyright © 2023 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1532-6500
- Volume :
- 32
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Journal of shoulder and elbow surgery
- Publication Type :
- Academic Journal
- Accession number :
- 37276917
- Full Text :
- https://doi.org/10.1016/j.jse.2023.05.002