Back to Search
Start Over
Greater Outflow Facility Increase After Targeted Trabecular Bypass in Angiographically Determined Low-low Regions.
- Source :
-
Ophthalmology. Glaucoma [Ophthalmol Glaucoma] 2023 Nov-Dec; Vol. 6 (6), pp. 570-579. Date of Electronic Publication: 2023 Jun 20. - Publication Year :
- 2023
-
Abstract
- Purpose: To investigate the impact of trabecular bypass surgery targeted to angiographically determined high- vs. low-aqueous humor outflow areas on outflow facility (C) and intraocular pressure (IOP).<br />Design: Ex vivo comparative study.<br />Subjects: Postmortem ex vivo porcine and human eyes.<br />Methods: Porcine (n = 14) and human (n = 13) whole globes were acquired. In both species, anterior segments were dissected, mounted onto a perfusion chamber, and perfused using Dulbecco's phosphate buffered solution containing glucose in a constant flow paradigm to achieve a stable baseline. Fluorescein was perfused into the anterior chamber and used to identify baseline segmental high- and low-flow regions of the conventional outflow pathways. The anterior segments were divided into 2 groups, and a 5 mm needle goniotomy was performed in either a high- or low-flow area. Subsequently, C and IOP were quantitatively reassessed and compared between surgery in baseline "high-flow" and "low-flow" region eyes followed by indocyanine green angiography.<br />Main Outcome Measures: Outflow facility.<br />Results: In all eyes, high- and low-flow segments could be identified. Performing a 5-mm goniotomy increased outflow facility to a variable extent depending on baseline flow status. In the porcine high-flow group, C increased from 0.31 ± 0.09 to 0.39 ± 0.09 μL/mmHg/min (P = 0.12). In the porcine low-flow group, C increased from 0.29 ± 0.03 to 0.56 ± 0.10 μL/mmHg/min (P < 0.001). In the human high-flow group, C increased from 0.38 ± 0.20 to 0.41 ± 0.20 μL/mmHg/min (P = 0.02). In the human low-flow group, C increased from 0.25 ± 0.11 to 0.32 ± 0.11 μL/mmHg/min (<0.001). There was statistically significant greater increase in C for eyes where surgery was targeted to baseline low-flow regions in both porcine (0.07 ± 0.09 vs. 0.27 ± 0.13, P = 0.007 μL/mmHg/min, high vs low flow) and human eyes (0.03 ± 0.03 vs. 0.07 ± 0.02, P = 0.03 μL/mmHg/min, high vs. low flow).<br />Conclusions: Targeting surgery to low-flow areas of the trabecular meshwork yields higher overall facility increase and IOP reduction compared to surgery in high-flow areas.<br />Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.<br /> (Copyright © 2023 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2589-4196
- Volume :
- 6
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Ophthalmology. Glaucoma
- Publication Type :
- Academic Journal
- Accession number :
- 37348815
- Full Text :
- https://doi.org/10.1016/j.ogla.2023.06.008