Simulation and evaluation of increased imaging service capacity at the MRI department using reduced coil-setting times.

Authors :
Sun YC
Wu HM
Guo WY
Ou YY
Yao MJ
Lee LH
Source :
PloS one [PLoS One] 2023 Jul 27; Vol. 18 (7), pp. e0288546. Date of Electronic Publication: 2023 Jul 27 (Print Publication: 2023).
Publication Year :
2023

Abstract

The wait times for patients from their appointments to receiving magnetic resonance imaging (MRI) are usually long. To reduce this wait time, the present study proposed that service time wastage could be reduced by adjusting MRI examination scheduling by prioritizing patients who require examinations involving the same type of coil. This approach can reduce patient wait times and thereby maximize MRI departments' service times. To simulate an MRI department's action workflow, 2,447 MRI examination logs containing the deidentified information of patients and radiation technologists from the MRI department of a medical center were used, and a hybrid simulation model that combined discrete-event and agent-based simulations was developed. The experiment was conducted in two stages. In the first stage, the service time was increased by adjusting the examination schedule and thereby reducing the number of coil changes. In the second stage, the maximum number of additional patients that could be examined daily was determined. The average number of coil changes per day for the four MRI scanners of the aforementioned medical center was reduced by approximately 27. Thus, the MRI department gained 97.17 min/d, which enabled them to examine three additional patients per month. Consequently, the net monthly income of the hospital increased from US$17,067 to US$30,196, and the patient wait times for MRI examinations requiring the use of flexible torso and head, shoulder, 8-inch head, and torso MRI coils were shortened by 6 d and 23 h, 2 d and 15 h, 2 d and 9 h, and 16 h, respectively. Adjusting MRI examination scheduling by prioritizing patients that require the use of the same coil could reduce the coil-setting time, increase the daily number of patients who are examined, increase the net income of the MRI department, and shorten patient wait times for MRI examinations. Minimizing the operating times of specific examinations to maximize the number of services provided per day does not require additional personnel or resources. The results of the experimental simulations can be used as a reference by radiology department managers designing scheduling rules for examination appointments.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2023 Sun et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
18
Issue :
7
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
37498942
Full Text :
https://doi.org/10.1371/journal.pone.0288546