Back to Search Start Over

Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique.

Authors :
Pirola S
Pirola S
Mastroiacovo G
Bonomi A
Manchester EL
Fisichella SM
Maragna R
Baggiano A
Mushtaq S
Muscogiuri G
Guglielmo M
Yun Xu X
Pontone G
Polvani G
Source :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2023 Dec 01; Vol. 64 (6).
Publication Year :
2023

Abstract

Objectives: Aortic valve neocuspidalization aims to replace the 3 aortic cusps with autologous pericardium pre-treated with glutaraldehyde, and it is a surgical alternative to the classical aortic valve replacement (AVR). Image-based patient-specific computational fluid dynamics allows the derivation of shear stress on the aortic wall [wall shear stress (WSS)]. Previous studies support a potential link between increased WSS and histological alterations of the aortic wall. The aim of this study is to compare the WSS of the ascending aorta in patients undergoing aortic valve neocuspidalization versus AVR with biological prostheses.<br />Methods: This is a prospective nonrandomized clinical trial. Each patient underwent a 4D-flow cardiac magnetic resonance scan after surgery, which informed patient-specific computational fluid dynamics models to evaluate WSS at the ascending aortic wall. The adjusted variables were calculated by summing the residuals obtained from a multivariate linear model (with ejection fraction and left ventricle outflow tract-aorta angle as covariates) to the mean of the variables.<br />Results: Ten patients treated with aortic valve neocuspidalization were enrolled and compared with 10 AVR patients. The aortic valve neocuspidalization group showed a significantly lower WSS in the outer curvature segments of the proximal and distal ascending aorta as compared to AVR patients (P = 0.0179 and 0.0412, respectively). WSS levels remained significantly lower along the outer curvature of the proximal aorta in the aortic valve neocuspidalization population, even after adjusting the WSS for the ejection fraction and the left ventricle outflow tract-aorta angle [2.44 Pa (2.17-3.01) vs 1.94 Pa (1.72-2.01), P = 0.02].<br />Conclusions: Aortic valve neocuspidalization hemodynamical features are potentially associated with a lower WSS in the ascending aorta as compared to commercially available bioprosthetic valves.<br /> (© The Author(s) 2023. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)

Details

Language :
English
ISSN :
1873-734X
Volume :
64
Issue :
6
Database :
MEDLINE
Journal :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
Publication Type :
Academic Journal
Accession number :
37656941
Full Text :
https://doi.org/10.1093/ejcts/ezad299