Use of PROSE for long-term ocular surface support in patients with a permanent keratoprosthesis.
- Source :
-
American journal of ophthalmology case reports [Am J Ophthalmol Case Rep] 2023 Sep 01; Vol. 32, pp. 101919. Date of Electronic Publication: 2023 Sep 01 (Print Publication: 2023). - Publication Year :
- 2023
-
Abstract
- Purpose: To describe the long-term outcome of the use of a specialized scleral lens known as a prosthetic replacement of the ocular surface ecosystem (PROSE) device to support the ocular surface in patients with a Boston Keratoprosthesis (KPro) Type I. All patients in this series were unable to pursue continuous wear of a bandage soft contact lens (BSCL) - a critical aspect of post KPro implantation management intended to protect the corneal carrier tissue from desiccation and stromal melting.<br />Observations: Four eyes of four patients with a Boston KPro Type I were included. All four had failed BSCL wear and were instead treated with PROSE device wear. All four patients had underlying diagnoses associated with a diseased ocular surface (Stevens-Johnson Syndrome [one patient], prior failed penetrating keratoplasty associated with herpes zoster-related neurotrophic keratopathy [one patient], and prior failed penetrating keratoplasty associated with severe dry eye disease [two patients]). Causes of failure of BSCL wear included poor retention, discomfort, and poor vision. PROSE device wear was initiated on average seven and a half (range four to 14) months post-KPro implantation. The wear schedule varied and ranged from waking-hour wear only to 24-h wear. The average duration of device wear was 59.3 (range 28-103) months. Two patients exhibited persistent corneal epithelial defect formation with waking-hour wear, which resolved within 10 days with 24-h device wear. All patients exhibited improvement in vision with PROSE compared to baseline, averaging six and a half (range six to eight) lines of improvement in Snellen acuity, and all patients reported increased comfort. There was no incidence of microbial keratitis, KPro device instability, or other complication throughout the duration of device wear.<br />Conclusions and Importance: This report offers a novel alternate approach to long-term support of the ocular surface in patients with a Boston KPro who fail standard continuous BSCL wear.<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The authors report no financial conflicts of interest to report in regard to this work. Bita Asghari, Karen Carrasquillo, Alan Kwok are salaried clinical employees of BostonSight, Needham, MA.<br /> (© 2023 The Authors.)
Details
- Language :
- English
- ISSN :
- 2451-9936
- Volume :
- 32
- Database :
- MEDLINE
- Journal :
- American journal of ophthalmology case reports
- Publication Type :
- Report
- Accession number :
- 37705757
- Full Text :
- https://doi.org/10.1016/j.ajoc.2023.101919