Back to Search Start Over

Technical limits of sensitivity for EIT magnetometry.

Authors :
McKelvy JA
Maldonado MA
Novikova I
Mikhailov EE
Matsko AB
Source :
Applied optics [Appl Opt] 2023 Aug 20; Vol. 62 (24), pp. 6518-6527.
Publication Year :
2023

Abstract

Optical magnetometers based on electromagnetically induced transparency (EIT) in atomic vapor can in principle achieve outstanding sensitivity and accuracy in a small volume. Up until now, however, the predicted fundamental quantum-noise-limited sensitivity has not been achieved in practice due to various technical limitations associated with the measurement apparatus. Here we analyze these restrictions and propose viable mitigation strategies for performance optimization. As an example, we show that an EIT magnetometer can theoretically achieve sensitivity better than 100 fT at 1 s measurement time under realistic conditions.

Details

Language :
English
ISSN :
1539-4522
Volume :
62
Issue :
24
Database :
MEDLINE
Journal :
Applied optics
Publication Type :
Academic Journal
Accession number :
37706846
Full Text :
https://doi.org/10.1364/AO.497368