Back to Search Start Over

Impact of implant location on load distribution of implant-assisted removable partial dentures: a review of in vitro model and finite-element analysis studies.

Authors :
Ichikawa H
Yoda N
Ogawa T
Iwamoto M
Kawata T
Egusa H
Sasaki K
Source :
International journal of implant dentistry [Int J Implant Dent] 2023 Sep 19; Vol. 9 (1), pp. 31. Date of Electronic Publication: 2023 Sep 19.
Publication Year :
2023

Abstract

Background: Appropriate load distribution among the supporting elements is essential for the long-term success of implant-assisted removable partial dentures; however, there is little information available on load distribution.<br />Purpose: This study aimed to evaluate the effect of implant location on load distribution in implant-assisted removable partial dentures by reviewing in vitro models and finite-element analysis studies.<br />Materials and Methods: English-language studies which examined the load distribution of implant-assisted removable partial dentures and were published between January 2001 and October 2022 were extracted from PubMed, ScienceDirect, and Scopus online databases, and manual searching. Two reviewers selected the articles based on the predetermined inclusion and exclusion criteria, followed by data extraction and analysis.<br />Results: Forty-seven studies were selected after evaluating the titles and abstracts of 264 articles; two were identified manually. After screening the text, 12 studies were included: six in vitro model experiments and six finite-element analysis studies. All included studies used a mandibular free-end missing model (Kennedy Class I or II). The influence of implant location on load distribution to the abutment tooth, implant, and mucosa under the denture base was summarized in three cases: implant at the premolar, first molar, and second molar region. Due to differences in the measurement method of load distribution and loading condition to the denture, the results differed among the studies.<br />Conclusions: The implant location in implant-assisted removable partial dentures can affect load distribution to the supporting elements, such as the abutment tooth, implant, and mucosa under the denture base.<br /> (© 2023. Deutsche Gesellschaft für Implantologie im Zahn‐, Mund‐ und Kieferbereich e.V., Japanese Society of Oral Implantology.)

Details

Language :
English
ISSN :
2198-4034
Volume :
9
Issue :
1
Database :
MEDLINE
Journal :
International journal of implant dentistry
Publication Type :
Academic Journal
Accession number :
37725286
Full Text :
https://doi.org/10.1186/s40729-023-00500-3