Back to Search Start Over

Reversible Pulsed Electrical Fields as an In Vivo Tool to Study Cardiac Electrophysiology: The Advent of Pulsed Field Mapping.

Authors :
Koruth JS
Neuzil P
Kawamura I
Kuroki K
Petru J
Rackauskas G
Funasako M
Aidietis A
Reddy VY
Source :
Circulation. Arrhythmia and electrophysiology [Circ Arrhythm Electrophysiol] 2023 Oct; Vol. 16 (10), pp. e012018. Date of Electronic Publication: 2023 Sep 20.
Publication Year :
2023

Abstract

Background: During electrophysiological mapping of tachycardias, putative target sites are often only truly confirmed to be vital after observing the effect of ablation. This lack of mapping specificity potentiates inadvertent ablation of innocent cardiac tissue not relevant to the arrhythmia. But if myocardial excitability could be transiently suppressed at critical regions, their suitability as targets could be conclusively determined before delivering tissue-destructive ablation lesions. We studied whether reversible pulsed electric fields (PF <subscript>REV</subscript> ) could transiently suppress electrical conduction, thereby providing a means to dissect tachycardia circuits in vivo.<br />Methods: PF <subscript>REV</subscript> energy was delivered from a 9-mm lattice-tip catheter to the atria of 12 swine and 9 patients, followed by serial electrogram assessments. The effects on electrical conduction were explored in 5 additional animals by applying PF <subscript>REV</subscript> to the atrioventricular node: 17 low-dose (PF <subscript>REV-LOW</subscript> ) and 10 high-dose (PF <subscript>REV-HIGH</subscript> ) applications. Finally, in 3 patients manifesting spontaneous tachycardias, PF <subscript>REV</subscript> was applied at putative critical sites.<br />Results: In animals, the immediate post-PF <subscript>REV</subscript> electrogram amplitudes diminished by 74%, followed by 78% recovery by 5 minutes. Similarly, in patients, a 69.9% amplitude reduction was followed by 84% recovery by 3 minutes. Histology revealed only minimal to no focal, superficial fibrosis. PF <subscript>REV-LOW</subscript> at the atrioventricular node resulted in transient PR prolongation and transient AV block in 59% and 6%, while PF <subscript>REV-HIGH</subscript> caused transient PR prolongation and transient AV block in 30% and 50%, respectively. The 3 tachycardia patients had atypical atrial flutters (n=2) and atrioventricular nodal reentrant tachycardia. PF <subscript>REV</subscript> at putative critical sites reproducibly terminated the tachycardias; ablation rendered the tachycardias noninducible and without recurrence during 1-year follow-up.<br />Conclusions: Reversible electroporation pulses can be applied to myocardial tissue to transiently block electrical conduction. This technique of pulsed field mapping may represent a novel electrophysiological tool to help identify the critical isthmus of tachycardia circuits.<br />Competing Interests: Disclosures Dr Reddy: Affera-Medtronic: consultant, equity (stock); other disclosures not related to this article are detailed in the Supplemental Material. Dr Koruth: Affera-Medtronic: grant support, stock, consultant. Dr Neuzil: Affera-Medtronic: grant support.

Details

Language :
English
ISSN :
1941-3084
Volume :
16
Issue :
10
Database :
MEDLINE
Journal :
Circulation. Arrhythmia and electrophysiology
Publication Type :
Academic Journal
Accession number :
37727989
Full Text :