Eddy current-induced artifact correction in high b-value ex vivo human brain diffusion MRI with dynamic field monitoring.

Authors :
Ramos-Llordén G
Park DJ
Kirsch JE
Scholz A
Keil B
Maffei C
Lee HH
Bilgic B
Edlow BL
Mekkaoui C
Yendiki A
Witzel T
Huang SY
Source :
Magnetic resonance in medicine [Magn Reson Med] 2024 Feb; Vol. 91 (2), pp. 541-557. Date of Electronic Publication: 2023 Sep 27.
Publication Year :
2024

Abstract

Purpose: To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current-induced artifacts incurred by strong diffusion-sensitizing gradients up to 300 mT/m used in high b-value diffusion-weighted (DW) EPI.<br />Methods: A dynamic field camera equipped with 16 <superscript>1</superscript> H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi-shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring-based image reconstruction was demonstrated on high-gradient strength, submillimeter resolution whole-brain ex vivo diffusion MRI. A 3D multi-shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera.<br />Results: Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k-space trajectory. During the readout, phase modulations between odd and even EPI echoes become non-static and diffusion encoding direction-dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator- and structured low-rank-based methods or MUSE followed by image-based distortion correction with the FSL tool "eddy."<br />Conclusion: Strong eddy current artifacts characteristic of high-gradient strength DW-EPI can be well corrected with dynamic field monitoring-based image reconstruction.<br /> (© 2023 International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2594
Volume :
91
Issue :
2
Database :
MEDLINE
Journal :
Magnetic resonance in medicine
Publication Type :
Academic Journal
Accession number :
37753621
Full Text :
https://doi.org/10.1002/mrm.29873