Back to Search Start Over

Potential Approach to Quantifying the Volume of the Ischemic Core in Truncated Computed Tomography Perfusion Scans: A Preliminary Study.

Authors :
Xu XQ
Cao LL
Ma G
Shen GC
Lu SS
Zhang YX
Zhang Y
Shi HB
Liu S
Wu FY
Source :
Journal of computer assisted tomography [J Comput Assist Tomogr] 2024 Mar-Apr 01; Vol. 48 (2), pp. 298-302. Date of Electronic Publication: 2023 Aug 31.
Publication Year :
2024

Abstract

Objective: This study aimed to provide an alternative approach for quantifying the volume of the ischemic core (IC) if truncation of computed tomography perfusion (CTP) occurs in clinical practice.<br />Methods: Baseline CTP and follow-up diffusion-weighted imaging (DWI) data from 88 patients with stroke were retrospectively collected. CTP source images (CTPSI) from the unenhanced phase to the peak arterial phase (CTPSI-A) or the peak venous phase (CTPSI-V) were collected to simulate the truncation of CTP in the arterial or venous phases, respectively. The volume of IC on CTPSI-A (V CTPSI-A ) or CTPSI-V (V CTPSI-V ) was defined as the volume of the brain tissue with >65% reduction in attenuation compared with that of the normal tissue. The volume of IC on the baseline CTP (V CTP ) was defined as a relative cerebral blood flow of <30% of that in the normal tissue. The volume of the posttreatment infarct on the follow-up DWI (V DWI ) image was manually delineated and calculated. One-way analysis of variance, Bland-Altman plots, and Spearman correlation analyses were used for the statistical analysis.<br />Results: V CTPSI-A was significantly higher than V DWI ( P < 0.001); however, no significant difference was observed between V CTP and V DWI ( P = 0.073) or between V CTPSI-V and V DWI ( P > 0.999). The mean differences between V DWI and V CTPSI-V , V DWI and V CTP , and V DWI and V CTPSI-A were 1.70 mL (limits of agreement [LoA], -56.40 to 59.70), 8.30 mL (LoA, -40.70 to 57.30), and -68.10 mL (LoA, -180.90 to 44.70), respectively. Significant correlations were observed between V DWI and V CTP ( r = 0.68, P < 0.001) and between V DWI and V CTPSI-V ( r = 0.39, P < 0.001); however, no significant correlation was observed between V DWI and V CTPSI-A ( r = 0.20, P = 0.068).<br />Conclusions: V CTPSI-V may be a promising method for quantifying the volume of the IC if truncation of CTP occurs.<br />Competing Interests: The authors declare no conflict of interest.<br /> (Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-3145
Volume :
48
Issue :
2
Database :
MEDLINE
Journal :
Journal of computer assisted tomography
Publication Type :
Academic Journal
Accession number :
37757843
Full Text :
https://doi.org/10.1097/RCT.0000000000001552