Back to Search Start Over

50-W vs 40-W During High-Power Short-Duration Ablation for Paroxysmal Atrial Fibrillation: A Multicenter Prospective Study.

Authors :
Costea A
Diaz JC
Osorio J
Matos CD
Hoyos C
Goyal S
Te C
D'Souza B
Rastogi M
Lopez-Cabanillas N
Ibanez LC
Thorne C
Varley AL
Zei PC
Sauer WH
Romero JE
Source :
JACC. Clinical electrophysiology [JACC Clin Electrophysiol] 2023 Dec; Vol. 9 (12), pp. 2573-2583. Date of Electronic Publication: 2023 Oct 04.
Publication Year :
2023

Abstract

Background: High-power short-duration (HPSD) radiofrequency ablation of atrial fibrillation (AF) increases first-pass pulmonary vein isolation (PVI) and freedom from atrial arrhythmias while decreasing procedural time. However, the optimal power setting in terms of safety and efficacy has not been determined.<br />Objectives: This study compared the procedural characteristics and clinical outcomes of 50-W vs 40-W during HPSD ablation of paroxysmal AF.<br />Methods: Patients from the REAL-AF prospective multicenter registry (Real-World Experience of Catheter Ablation for Treatment of Symptomatic Paroxysmal and Persistent Atrial Fibrillation) undergoing HPSD ablation of paroxysmal AF, either using 50-W or 40-W, were included. The primary efficacy outcome was freedom from all-atrial arrhythmias. The primary safety outcome was the occurrence of any procedural complication at 12 months. Secondary outcomes included procedural characteristics, AF-related symptoms, and the occurrence of transient ischemic attack or stroke at 12 months.<br />Results: A total of 383 patients were included. Freedom from all-atrial arrhythmias at 12 months was 80.7% in the 50-W group and 77.3% in the 40-W group (Log-rank P = 0.387). The primary safety outcome occurred in 3.7% of patients in the 50-W group vs 2.8% in the 40-W group (P = 0.646). The 50-W group had a higher rate of first-pass PVI (82.3% vs 76.2%; P = 0.040) as well as shorter procedural (67 minutes [IQR: 54-87.5 minutes] vs 93 minutes [IQR: 80.5-111 minutes]; P < 0.001) and radiofrequency ablation times (15 minutes [IQR: 11.4-20 minutes] vs 27 minutes [IQR: 21.5-34.6 minutes]; P < 0.001) than the 40-W group.<br />Conclusions: There was no significant difference in freedom from all-atrial arrhythmias or procedural safety outcomes between 50-W and 40-W during HPSD ablation of paroxysmal AF. The use of 50-W was associated with a higher rate of first-pass PVI as well as shorter procedural times.<br />Competing Interests: Funding Support and Author Disclosures The REAL-AF registry is funded through an investigator-initiated research grant (PI: Dr Osorio) from Biosense Webster Inc (NCT04088071). Drs Osorio, Zei, and Romero have received consulting and research support from Biosense Webster. Dr D’Souza has received consulting support from Biosense Webster. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.<br /> (Copyright © 2023 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
2405-5018
Volume :
9
Issue :
12
Database :
MEDLINE
Journal :
JACC. Clinical electrophysiology
Publication Type :
Academic Journal
Accession number :
37804258
Full Text :