Back to Search
Start Over
Paroxysmal atrial fibrillation ablation with a novel temperature-controlled CF-sensing catheter: Q-FFICIENCY clinical and healthcare utilization benefits.
- Source :
-
Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2023 Dec; Vol. 34 (12), pp. 2493-2503. Date of Electronic Publication: 2023 Oct 23. - Publication Year :
- 2023
-
Abstract
- Introduction: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants.<br />Methods: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization.<br />Results: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively.<br />Conclusions: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.<br /> (© 2023 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.)
- Subjects :
- Humans
Prospective Studies
Quality of Life
Temperature
Treatment Outcome
Catheters
Anti-Arrhythmia Agents therapeutic use
Patient Acceptance of Health Care
Atrial Fibrillation diagnosis
Atrial Fibrillation surgery
Atrial Fibrillation drug therapy
Pulmonary Veins surgery
Catheter Ablation adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1540-8167
- Volume :
- 34
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 37870157
- Full Text :
- https://doi.org/10.1111/jce.16093