Reduction of airborne and surface-borne bacteria in a medical center burn intensive care unit using active, upper-room, germicidal ultraviolet (GUV) disinfection.

Authors :
Lee LD
Lie L
Bauer M
Bolanos B
Olmsted RN
Varma JK
Parada JP
Source :
Infection control and hospital epidemiology [Infect Control Hosp Epidemiol] 2024 Mar; Vol. 45 (3), pp. 367-373. Date of Electronic Publication: 2023 Oct 25.
Publication Year :
2024

Abstract

Objective: To determine the effectiveness of active, upper-room, germicidal ultraviolet (GUV) devices in reducing bacterial contamination in patient rooms in air and on surfaces as a supplement to the central heating, ventilation, and air conditioning (HVAC) air handling unit (AHU) with MERV 14 filters and UV-C disinfection.<br />Methods: This study was conducted in an academic medical center, burn intensive care unit (BICU), for 4 months in 2022. Room occupancy was monitored and recorded. In total, 402 preinstallation and postinstallation bacterial air and non-high-touch surface samples were obtained from 10 BICU patient rooms. Airborne particle counts were measured in the rooms, and bacterial air samples were obtained from the patient-room supply air vents and outdoor air, before and after the intervention. After preintervention samples were obtained, an active, upper-room, GUV air disinfection system was deployed in each of the patient rooms in the BICU.<br />Results: The average levels of airborne bacteria of 395 CFU/m <superscript>3</superscript> before GUV device installation and 37 CFU/m <superscript>3</superscript> after installation indicated an 89% overall decrease ( P < .0001). Levels of surface-borne bacteria were associated with a 69% decrease ( P < .0001) after GUV device installation. Outdoor levels of airborne bacteria averaged 341 CFU/m <superscript>3</superscript> in March before installation and 676 CFU/m <superscript>3</superscript> in June after installation, but this increase was not significant ( P = .517).<br />Conclusions: Significant reductions in air and surface contamination occurred in all rooms and areas and were not associated with variations in outdoor air concentrations of bacteria. The significant decrease of surface bacteria is an unexpected benefit associated with in-room GUV air disinfection, which can potentially reduce overall bioburden.

Details

Language :
English
ISSN :
1559-6834
Volume :
45
Issue :
3
Database :
MEDLINE
Journal :
Infection control and hospital epidemiology
Publication Type :
Academic Journal
Accession number :
37877197
Full Text :
https://doi.org/10.1017/ice.2023.223